• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, stop the 

operation of the air conditioner, consult your 
local dealer.

Regarding drainage of drain piping

• Is the drain piping carried out properly to 

ensure complete drainage?

If drain piping is not carried out properly, dirt and 
debris may be accumulated in the drain piping 
and cause water leakage. If it occurs, stop the air 
conditioner and consult with your local dealer for 
assistance.

Operating procedure varies with heat pump type 
and cooling only type. Contact your local dealer to 
confirm your system type.

To protect the air conditioner, turn on the main 
power switch 6 hours before operation.

Do not shut off the power supply during seasonal 
use of the air conditioner.
This is required in order to activate the air condi-
tioner smoothly.

If the main power supply is turned off during oper-
ation, operation will restart automatically after the 
power turns back on again.

5-1. FUQ

Read the operation manual attached to the 
remote controller.

5-2. FXUQ

Read the operation manual attached to the out-
door unit and remote controller.

CHARACTERISTICS OF THE COOLING 
OPERATION (COOLING OPERATION AND 
AUTOMATIC COOLING OPERATION)

If the COOLING OPERATION is used when the 
indoor temperature is low, frost adheres to the 
heat exchanger of the indoor unit. 
This can decrease the cooling capacity. 
In this case, the air conditioner automatically 
switches to the DEFROST OPERATION for a 
while.

5. OPERATION PROCEDURE

6. OPERATION CHARACTERIS-

TICS

During the DEFROST OPERATION, the low fan 
speed or a gentle wind is used to prevent the dis-
charge of melt water. 
(The remote controller displays the fan speed that 
is set.) 

When the outdoor temperature is high, it takes 
some time until the indoor temperature reaches 
the set temperature.

CHARACTERISTICS OF THE HEATING 
OPERATION (HEATING OPERATION AND 
AUTOMATIC HEATING OPERATION)

START OF OPERATION

It generally takes a longer time for indoor temper-
ature of the HEATING OPERATION to reach the 
set temperature compared to the COOLING 
OPERATION.
It is advisable to start operation in advance using 
the TIMER OPERATION.

Perform the following operation to prevent heat-
ing capacity decrease and discharge of cool air.

AT THE START OF OPERATION AND AFTER 
THE DEFROST OPERATION

A warm air circulating system is employed, and 
therefore it takes some time until the entire room 
is warmed up after the start of operation.

The indoor fan runs to discharge a gentle wind 
automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “

”. Leave it as 

it stands and wait for a while.
(The remote controller displays the fan speed that 
is set.)

The airflow direction becomes horizontal to pre-
vent a draft of cool air to the inhabitants. (The 
remote controller displays the set airflow direction 
that is set.) 

DEFROST OPERATION
(Frost removal operation for the outdoor 
unit)

As the frost on the coil of an outdoor unit increase, 
heating effect decreases and the air conditioner 
goes into the DEFROST OPERATION.

The indoor unit fan stops and the remote control-
ler display shows “

”.

With the wireless remote controller, the warm air 
stops, and the DEFROST OPERATION lamp on 
the light receiving unit turn on. 
(The remote controller displays the fan speed that 
is set.)

After maximum 10 minutes of the DEFROST 
OPERATION, the air conditioner returns to the 
HEATING OPERATION.

01_EN_3P170549-16W.fm  Page 6  Thursday, February 20, 2014  5:28 PM

Summary of Contents for FUQ100CVEB

Page 1: ...MANUAL MODELS 4 Way Blow Ceiling Suspended type SPLIT SYSTEM VRV SYSTEM FUQ71CVEB FXUQ71AVEB FUQ100CVEB FXUQ100AVEB FUQ125CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugu s T rk e 00...

Page 2: ...rdelo para futuras consultas Asimismo aseg rese de entregar este manual de instrucciones a un nuevo usuario Debido a que este manual de instrucciones est dedi cado a la unidad interior deber consultar...

Page 3: ...tes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especial izadas para su r...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched so...

Page 6: ...he control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove the...

Page 7: ...s a customized control system ask your local dealer for the operation that corre sponds to your system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Page 8: ...t bulb temperature The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ Read the operation manual attached to the out door unit Regarding places for installation Istheairco...

Page 9: ...is used to prevent the dis charge of melt water The remote controller displays the fan speed that is set When the outdoor temperature is high it takes some time until the indoor temperature reaches th...

Page 10: ...r the indoor temperature and humidity first use the COOLING OPERATION to lower the indoor temperature and then use the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the ind...

Page 11: ...conditioner It may decrease the effect or stop the operation Adjust the room temperature properly for a com fortable environment Avoid excessive heating or cooling Not doing so wastes electricity When...

Page 12: ...r filter It indicates after running for a certain time NOTE You may change the time of indication or Time to clean filter If the indoor unit is used in a space where the air is more contaminated ask y...

Page 13: ...ched to the indoor unit Refer to the figure shown below Suction grille Strap Knob Knob 2 Open the suction grille to 45 and lift it Then unhook it from the place to hook 3 places 3 Take out the air fil...

Page 14: ...order to activate the air condi tioner smoothly and to protect the air conditioner The display on the remote controller will be shown when the power circuit breaker is turned on HEATING OPERATION wit...

Page 15: ...installation but every time the power cir cuit breaker is turned off on 9 NOT MALFUNCTION OF THE AIR CONDITIONER For comfortable use do not turn off the power circuit breaker during seasonal use of t...

Page 16: ...unit Ask your local dealer for details on cleaning the indoor unit This cleaning requires a qualified service person Check the usage environment When the air conditioner is changed over to the HEATIN...

Page 17: ...vers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove the obstacle and make it well venti la...

Page 18: ...his time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditio...

Page 19: ...3P170549 16W EM12A001A 1404 HT 00_CV_3P170549 16W_01 fm Page 2 Saturday February 15 2014 6 19 PM...

Reviews: