background image

3 About the box

Installation manual

8

FTXTP-M_FTXTP-N

Daikin room air conditioner

3P650253-16U – 2023.03

3

About the box

3.1

Indoor unit

3.1.1

To remove the accessories from the
indoor unit

1

Remove:

▪ the accessory bag located at the bottom of the package,

▪ the mounting plate attached to the back of the indoor unit.

e

d

b

a

c

f

g

h

i

j

a

Installation manual

b

Operation manual

c

General safety precautions

d

Titanium apatite deodorising filter and the silver particle
filter (Ag-ion filter)

e

Indoor unit fixing screw (M4×12L). Refer to 

"8.3 To fix the

unit on the mounting plate"

 [

4

 13].

f

Dry battery AAA.LR03 (alkaline) for user interface

g

User interface holder

h

User interface

i

Mounting plate

j

Wireless LAN adapter

4

About the unit

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

4.1

About the wireless LAN

▪ Wireless LAN adapter is part of the accessory bag.

For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit 

app.daikineurope.com

.

INFORMATION: Declaration of conformity

▪ Daikin  Industries  Czech  Republic  s.r.o.  declares  that

the  radio  equipment  type  inside  of  this  unit  is  in
compliance 

with 

Directive 

2014/53/EU 

and

S.I. 2017/1206: Radio Equipment Regulations 2017.

▪ This  unit  is  considered  as  combined  equipment

according to the definition of Directive 2014/53/EU and
S.I. 2017/1206: Radio Equipment Regulations 2017.

INFORMATION

Install  the  wireless  LAN  adapter  after  finishing  the  indoor
unit  installation.  Refer  to 

"9  Wireless  LAN  adapter

installation"

 [

4

 13].

4.1.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

4.1.2

Basic parameters

What

Value

Frequency range

2400 MHz~2483.5 MHz

Radio protocol

IEEE 802.11b/g/n

Radio frequency channel

1~11

Output power

0 dBm~18 dBm

Effective radiated power

17 dBm (11b) / 13 dBm (11g) /
12 dBm (11n)

Power supply

DC 14 V / 100 mA

5

Unit installation

INFORMATION

If  you  are  not  sure  how  to  open  or  close  parts  of  the  unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.  For  location  of  the  installer  reference  guide
see 

"1.1 About this document"

 [

4

 6].

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

5.1

Preparing the installation site

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

5.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

Air flow.

 Make sure nothing blocks the air flow.

Drainage.

  Make  sure  condensation  water  can  be  evacuated

properly.

Wall insulation

. When conditions in the wall exceed 30°C and a

relative  humidity  of  80%,  or  when  fresh  air  is  inducted  into  the
wall,  then  additional  insulation  is  required  (minimum  10  mm
thickness, polyethylene foam).

Wall  strength. 

Check  whether  the  wall  or  the  floor  is  strong

enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.

Spacing. 

Install the unit at least 1.8 m from the floor and keep the

following  requirements  in  mind  for  distances  from  the  walls  and
the ceiling:

Summary of Contents for FTXTP25N5V1B

Page 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXTP25M5V1B FTXTP35M5V1B FTXTP25N5V1B FTXTP35N5V1B...

Page 2: ...antis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu e s...

Page 3: ...h our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 1091 Electromagnetic Compatibility Regulatio...

Page 4: ...nstrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu e sa v robky p...

Page 5: ...tions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 follo...

Page 6: ...commissioning 15 11 2 To perform a test run 15 11 2 1 To perform a test run in winter season 15 12 Disposal 15 13 Technical data 15 13 1 Wiring diagram 15 13 1 1 Unified wiring diagram legend 15 1 Abo...

Page 7: ...UST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge...

Page 8: ...rol equipment E g automatic doors or fire alarm equipment This product may cause faulty behaviour of the equipment Microwave oven It may affect wireless LAN communications 4 1 2 Basic parameters What...

Page 9: ...ipe end d Through the wall hole 65 mm e Drain hose position 5 2 2 To drill a wall hole CAUTION For walls containing a metal frame or a metal board use a wall embedded pipe and wall cover in the feed t...

Page 10: ...kage from the plug 3 Insert the drain hose on the left side and do not forget to tighten it with the fixing screw otherwise water leakage may occur a b a b a Insulation fixing screw b Drain hose 4 Att...

Page 11: ...t piping and interconnection cable 412 NOTICE Make sure to insulate all refrigerant piping Any exposed piping might cause condensation 6 2 2 To check refrigerant piping joints for leaks after charging...

Page 12: ...About the documentation 46 3 Pass the interconnection cable from the outdoor unit through the feed through wall hole through the back of the indoor unit and through the front side Note In case the in...

Page 13: ...3 Press the bottom edge of the indoor unit with both hands until it is firmly caught by the mounting plate hooks 4 Secure the indoor unit to the mounting plate using 2 indoor unit fixing screws M4 12L...

Page 14: ...ONECTA application 9 2 1 To install the ONECTA app 1 Go to Google Play for Android devices or the App Store for iOS devices and search for ONECTA 2 Follow the directions on the screen to install the...

Page 15: ...that all functions and parts are working properly 1 In cooling mode select the lowest programmable temperature In heating mode select the highest programmable temperature Test run can be disabled if...

Page 16: ...Reactor M Stepper motor M C Compressor motor M F Fan motor M P Drain pump motor M S Swing motor MR MRCW MRM MRN Magnetic relay N Neutral n N Number of passes through ferrite core PAM Pulse amplitude m...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P650253 16U 2023 03 Copyright 2...

Reviews: