3 About the box
Installation manual
8
FTXTP-M_FTXTP-N
Daikin room air conditioner
3P650253-16U – 2023.03
3
About the box
3.1
Indoor unit
3.1.1
To remove the accessories from the
indoor unit
1
Remove:
▪ the accessory bag located at the bottom of the package,
▪ the mounting plate attached to the back of the indoor unit.
1×
2×
2×
2×
1×
1×
1×
1×
1×
1×
e
d
b
a
c
f
g
h
i
j
a
Installation manual
b
Operation manual
c
General safety precautions
d
Titanium apatite deodorising filter and the silver particle
filter (Ag-ion filter)
e
Indoor unit fixing screw (M4×12L). Refer to
13].
f
Dry battery AAA.LR03 (alkaline) for user interface
g
User interface holder
h
User interface
i
Mounting plate
j
Wireless LAN adapter
4
About the unit
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
4.1
About the wireless LAN
▪ Wireless LAN adapter is part of the accessory bag.
For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit
.
INFORMATION: Declaration of conformity
▪ Daikin Industries Czech Republic s.r.o. declares that
the radio equipment type inside of this unit is in
compliance
with
Directive
2014/53/EU
and
S.I. 2017/1206: Radio Equipment Regulations 2017.
▪ This unit is considered as combined equipment
according to the definition of Directive 2014/53/EU and
S.I. 2017/1206: Radio Equipment Regulations 2017.
INFORMATION
Install the wireless LAN adapter after finishing the indoor
unit installation. Refer to
4.1.1
Precautions when using the wireless LAN
Do NOT use near:
▪
Medical equipment.
E.g. persons using cardiac pacemakers or
defibrillators.
This
product
may
cause
electromagnetic
interference.
▪
Auto-control equipment.
E.g. automatic doors or fire alarm
equipment. This product may cause faulty behaviour of the
equipment.
▪
Microwave oven.
It may affect wireless LAN communications.
4.1.2
Basic parameters
What
Value
Frequency range
2400 MHz~2483.5 MHz
Radio protocol
IEEE 802.11b/g/n
Radio frequency channel
1~11
Output power
0 dBm~18 dBm
Effective radiated power
17 dBm (11b) / 13 dBm (11g) /
12 dBm (11n)
Power supply
DC 14 V / 100 mA
5
Unit installation
INFORMATION
If you are not sure how to open or close parts of the unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures. For location of the installer reference guide
see
6].
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
5.1
Preparing the installation site
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
5.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
▪
Air flow.
Make sure nothing blocks the air flow.
▪
Drainage.
Make sure condensation water can be evacuated
properly.
▪
Wall insulation
. When conditions in the wall exceed 30°C and a
relative humidity of 80%, or when fresh air is inducted into the
wall, then additional insulation is required (minimum 10 mm
thickness, polyethylene foam).
▪
Wall strength.
Check whether the wall or the floor is strong
enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.
▪
Spacing.
Install the unit at least 1.8 m from the floor and keep the
following requirements in mind for distances from the walls and
the ceiling: