4 About the unit

Installation manual

4

FTXTA30C2V1B(W)(B)

Daikin room conditioner

3P697375-7H – 2023.09

d

Titanium apatite deodorising filter and silver particle filter
(Ag-ion filter)

e

Indoor unit fixing screw (M4×12L). Refer to 

"8.3 To fix the

unit on the mounting plate"

 [

4

 9].

f

Dry battery AAA.LR03 (alkaline) for the wireless remote
control

g

Wireless remote control (user interface) holder

h

Wireless remote control (user interface)

i

Mounting plate

j

Screw cover

k

Spare SSID sticker with release paper (attached to the
unit)

Spare SSID sticker. 

Do NOT throw away the spare sticker. Keep

it  in  a  safe  place  in  case  it  is  needed  in  future  (e.g.  in  case  the
front grille was replaced attach it to the new front grille).

4

About the unit

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

4.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Cooling and

drying

(a)(b)

Heating

(a)

Outdoor temperature

–10~46°C DB

–30~24°C DB

Indoor temperature

18~32°C DB

10~30°C DB

Indoor humidity

≤80%

(a)

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

4.2

About the wireless LAN

For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit 

app.daikineurope.com

.

INFORMATION: Declaration of conformity

▪ Daikin  Industries  Czech  Republic  s.r.o.  declares  that

the  radio  equipment  type  inside  of  this  unit  is  in
compliance 

with 

Directive 

2014/53/EU 

and

S.I. 2017/1206: Radio Equipment Regulations 2017.

▪ This  unit  is  considered  as  combined  equipment

according to the definition of Directive 2014/53/EU and
S.I. 2017/1206: Radio Equipment Regulations 2017.

4.2.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

4.2.2

Basic parameters

Parameter

Value

Frequency range

2400 MHz~2483.5 MHz

Radio protocol

IEEE 802.11b/g/n

Radio frequency channel

1~13

Output power

13 dBm

Effective radiated power

15 dBm (11b) /14 dBm (11g) /
14 dBm (11n)

Power supply

DC 14 V / 100 mA

5

Unit installation

INFORMATION

If  you  are  not  sure  how  to  open  or  close  parts  of  the  unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.  For  location  of  the  installer  reference  guide
see 

"1.1 About this document"

 [

4

 2].

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

5.1

Preparing the installation site

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

5.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

Air flow.

 Make sure nothing blocks the air flow.

Drainage.

  Make  sure  condensation  water  can  be  evacuated

properly.

Wall insulation

. When conditions in the wall exceed 30°C and a

relative  humidity  of  80%,  or  when  fresh  air  is  inducted  into  the
wall,  then  additional  insulation  is  required  (minimum  10  mm
thickness, polyethylene foam).

Wall  strength. 

Check  whether  the  wall  or  the  floor  is  strong

enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.

Spacing. 

Install the unit at least 1.8 m from the floor and keep the

following  requirements  in  mind  for  distances  from  the  walls  and
the ceiling:

≥50

≥50

≥30

(mm)

Summary of Contents for FTXTA30C2V1BB

Page 1: ...Installation manual Daikin room conditioner English Installation manual Daikin room conditioner FTXTA30C2V1BW FTXTA30C2V1BB...

Page 2: ...mote control 10 11 Disposal 10 12 Technical data 10 12 1 Wiring diagram 10 12 1 1 Unified wiring diagram legend 10 1 About the documentation 1 1 About this document WARNING Make sure installation serv...

Page 3: ...n site and all electrical construction MUST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NO...

Page 4: ...rsons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may cause faulty be...

Page 5: ...a a a a h 610 605 555 k j i a Recommended mounting plate fixing spots g Value for tape measure b Pocket for the pipe port cover h Position for tape measure at symbol c Use tape measure as shown i Drai...

Page 6: ...side left back or left bottom INFORMATION The factory default is right side piping For left side piping remove the piping from the right side and install it on the left side 1 Remove the insulation fi...

Page 7: ...as possible 1 Connect refrigerant piping to the unit using flare connections 2 Wrap the refrigerant piping connection using vinyl tape overlapping at least half the width of the tape with each turn Ke...

Page 8: ...ce between both wirings should ALWAYS be at least 50 mm Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice 1...

Page 9: ...the pipe path marking on the mounting plate c c d e a b a Drain hose b Caulk this hole with putty or caulking material c Adhesive vinyl tape d Insulation tape e Mounting plate accessory NOTICE Do NOT...

Page 10: ...the indoor and outdoor units There are NO refrigerant leaks The correct pipe size is installed and the pipes are properly insulated The stop valves gas and liquid on the outdoor unit are fully open 10...

Page 11: ...KFR KHuR K M Magnetic relay L Live L Coil L R Reactor M Stepper motor M C Compressor motor M F Fan motor M P Drain pump motor M S Swing motor MR MRCW MRM MRN Magnetic relay N Neutral n N Number of pas...

Page 12: ...3P697375 7H 2023 09 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Reviews: