background image

English

6

3.

Installing the indoor unit

• The recommended installation method is back piping. 

When performing bottom piping or left side piping, refer to “3-2. Left-side, left-back, or left-bottom piping”.

• Right side piping cannot be performed. 
• In the case of bending or curing refrigerant pipes, keep the following precautions in mind.

Abnormal sound may be generated if improper work is conducted.
• Do not strongly press the refrigerant pipes onto the bottom frame.
• Do not strongly press the refrigerant pipes on the front grille, either.

3-1. Right-back or right-bottom piping 

1) Attach the drain hose to the underside of the 

refrigerant pipes with adhesive vinyl tape.

2) Wrap the refrigerant pipes and drain hose 

together with 

 insulation tape. 

3) Pass the drain hose and refrigerant pipes 

through the wall hole, then position the indoor 

unit on the 

 mounting plate hooks, using the 

 markings at the top of the indoor unit as a 

guide. 

3-2. Left-side, left-back, or left-bottom piping

1) Switch around the drain plug and drain hose.

 

2) Attach the drain hose to the underside of the refrigerant 

pipes with adhesive vinyl tape.

3) Shape the refrigerant pipes along the pipe path marking 

on the 

 mounting plate.

How to remove the pipe port cover 

1) Cut off the pipe port cover (on the bottom of the 

front grille) with a copping saw.
Apply the blade of the copping saw to the notch, 
and cut off the pipe port cover along the uneven 
inner surface.

2) After cutting off the pipe port cover, perform filing.

Remove the burrs along the cut section using a half 
round needle file.

NOTE

• Be careful not to let chips enter the driving section of the arm.
• Be careful not to put pressure on the lower front panel.

Right-bottom piping

Right-back piping

Remove pipe port cover 

here for right-bottom 

piping.

Bind refrigerant pipe and 

drain hose together with

    insulation tape.

K

A Mounting plate

K

A

Front grille side

The 

fi

gure shows the case of left-bottom piping.

3) Switch around the drain hose and drain plug.

1) Remove the fixing screw and 

pull out the drain hose.

How to switch around the drain plug and drain hose

2) Pull out 

drain plug.

Push the drain plug all the 

way in using a hexagonal 

wrench (3/16 inch (4mm)).

Hexagonal wrench 

(3/16 inch (4mm))

Drain plug

No gap

Do not apply lubricating oil 

(refrigerant oil) to the drain 

plug when inserting it.

The application of lubrication 

oil to the drain plug will 

deteriorate the plug to cause 

drain leakage from the plug.

Insert a hexagonal 

wrench (3/16 inch (4mm)).

Insert drain hose securely 

and fix in place with fixing 

screw.

Drain hose

Fixing screw

Drain hose

     Pull out 

drain hose.

2

1

     Remove fixing 

screw.

Remove pipe port cover here for 

left-bottom piping.

Remove pipe port 

cover here for 

left-side piping.

Left-bottom piping

Left-side piping
Left-back piping

A

01_EN_3P674703-1.fm  6 ページ  2022年3月29日 火曜日 午後3時40分

Summary of Contents for FTXR09WVJUW9

Page 1: ...R CONDITIONER R410A Split Series English Fran ais Espa ol MODELS FTXR09WVJUW9 FTXR12WVJUW9 FTXR18WVJUW9 FTXR09WVJUS9 FTXR12WVJUS9 FTXR18WVJUS9 Installation manual Manuel d installation Manual de insta...

Page 2: ...ials used for transportation may cause injuries or death by suffocation WARNING Only qualified personnel licensed or certified in their jurisdiction must carry out the installation work Installation m...

Page 3: ...tem b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet radiation R410A can contribute to the greenhouse e...

Page 4: ...the unit is away from electronic ignition type fluorescent lamps inverter or rapid start type as they may affect the remote controller range 9 no laundry equipment is nearby 2 Wireless remote controll...

Page 5: ...filters Screws M4 5 8 M4 16mm C D Wireless remote controller E Remote controller holder When dismounting the front grille refer to 2 Removing and installing the front grille on page 11 A Mounting plat...

Page 6: ...the pipe hole gap with putty Recommended mounting plate retention spots 5 spots in all Bolt size 3 8 M10 Bolt size 3 8 M10 Gas pipe end Liquid pipe end Place a leveler on these tabs Through the wall...

Page 7: ...h a copping saw Apply the blade of the copping saw to the notch and cut off the pipe port cover along the uneven inner surface 2 After cutting off the pipe port cover perform filing Remove the burrs a...

Page 8: ...le side and unit side 2 After cutting off the pipe port cover perform filing Remove the burrs along the cut section using a half round needle file NOTE Be careful not to let chips enter the driving se...

Page 9: ...the removal method on page 11 4 Remove the conduit mounting plate and then secure the conduit to the conduit mounting plate with the lock nut as shown in the illustration 5 Strip wire ends 3 4 inch 20...

Page 10: ...match the hose front end Figure of hose front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section o...

Page 11: ...ng finishing tape bundle and wrap the indoor unit piping and drain hose together so that the drain hose is below the other piping Piping size Minimum bend radius Piping thickness Thermal insulation si...

Page 12: ...t panel locks on the back of the front panel upward to release the locks left and right sides 2 Insert the panel shafts on both sides of the upper front panel into the shaft holes 3 Slide the front pa...

Page 13: ...f the two units When cutting the jumper be careful not to damage any of the surrounding parts 1 Remove the upper front panel and front grille Refer to the removal method on page 11 2 Cut the address j...

Page 14: ...ot interfere with the printed circuit board 3 Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure Attachment methods for metal plate electri...

Page 15: ...consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Test ite...

Page 16: ...2203 HT M21B356 The two dimensional bar code is a manufacturing code 3P674703 1 00_CV_3P674703 1 fm 2...

Reviews: