background image

INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER

R410A Split Series

English

Français

Español

MODELS

FTXR09WVJUW9
FTXR12WVJUW9
FTXR18WVJUW9
FTXR09WVJUS9
FTXR12WVJUS9
FTXR18WVJUS9

Installation manual

Manuel d’installation

Manual de instalación

EMURA

00_CV_3P674703-1.fm  1 ページ  2022年3月31日 木曜日 午前9時49分

Summary of Contents for FTXR09WVJUW9

Page 1: ...R CONDITIONER R410A Split Series English Fran ais Espa ol MODELS FTXR09WVJUW9 FTXR12WVJUW9 FTXR18WVJUW9 FTXR09WVJUS9 FTXR12WVJUS9 FTXR18WVJUS9 Installation manual Manuel d installation Manual de insta...

Page 2: ...ials used for transportation may cause injuries or death by suffocation WARNING Only qualified personnel licensed or certified in their jurisdiction must carry out the installation work Installation m...

Page 3: ...tem b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet radiation R410A can contribute to the greenhouse e...

Page 4: ...the unit is away from electronic ignition type fluorescent lamps inverter or rapid start type as they may affect the remote controller range 9 no laundry equipment is nearby 2 Wireless remote controll...

Page 5: ...filters Screws M4 5 8 M4 16mm C D Wireless remote controller E Remote controller holder When dismounting the front grille refer to 2 Removing and installing the front grille on page 11 A Mounting plat...

Page 6: ...the pipe hole gap with putty Recommended mounting plate retention spots 5 spots in all Bolt size 3 8 M10 Bolt size 3 8 M10 Gas pipe end Liquid pipe end Place a leveler on these tabs Through the wall...

Page 7: ...h a copping saw Apply the blade of the copping saw to the notch and cut off the pipe port cover along the uneven inner surface 2 After cutting off the pipe port cover perform filing Remove the burrs a...

Page 8: ...le side and unit side 2 After cutting off the pipe port cover perform filing Remove the burrs along the cut section using a half round needle file NOTE Be careful not to let chips enter the driving se...

Page 9: ...the removal method on page 11 4 Remove the conduit mounting plate and then secure the conduit to the conduit mounting plate with the lock nut as shown in the illustration 5 Strip wire ends 3 4 inch 20...

Page 10: ...match the hose front end Figure of hose front end When drain hose requires extension obtain an extension hose with an inner diameter of 5 8 inch 16mm Be sure to thermally insulate the indoor section o...

Page 11: ...ng finishing tape bundle and wrap the indoor unit piping and drain hose together so that the drain hose is below the other piping Piping size Minimum bend radius Piping thickness Thermal insulation si...

Page 12: ...t panel locks on the back of the front panel upward to release the locks left and right sides 2 Insert the panel shafts on both sides of the upper front panel into the shaft holes 3 Slide the front pa...

Page 13: ...f the two units When cutting the jumper be careful not to damage any of the surrounding parts 1 Remove the upper front panel and front grille Refer to the removal method on page 11 2 Cut the address j...

Page 14: ...ot interfere with the printed circuit board 3 Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure Attachment methods for metal plate electri...

Page 15: ...consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Test ite...

Page 16: ...2203 HT M21B356 The two dimensional bar code is a manufacturing code 3P674703 1 00_CV_3P674703 1 fm 2...

Reviews: