![background image](http://html1.mh-extra.com/html/daikin/ftxp20l2v1b/ftxp20l2v1b_installation-manual_3328555009.webp)
5 Installation
Installation manual
9
(A)(F)TXP20~7 FTXF20~71A2V1B
Daikin room air conditioner
3P512025-1C – 2018.01
To remove the electrical wiring box cover
1
Remove the front grille.
2
Remove 1 screw from the electrical wiring box.
3
Open the electrical wiring box cover by pulling the protruding
part on the top of the cover.
4
Unhook the tab on the bottom and remove the electrical wiring
box cover.
a
a
c
b
a
1
3
2
a
Tab
b
Protruding part on the top of the cover
c
Screw
5
To re-install the cover, first hook the bottom tab onto the
electrical wiring box, and slide the cover into the 2 upper tabs.
To open the service cover
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
a
b
a
Service cover screw
b
Service cover
5.2
Installing the indoor unit
5.2.1
To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall
using screws.
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.