3
|
Components
Service manual
86
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
a
A
A
ARXP-L + ARXP-M + RXP-L + RXP-M + RXP50~71N units
a
HAP LED
a
A
A
ARXP20~35N + RXP20~35N units
a
HAP LED
INFORMATION
Make sure the correct software is available on the PCB. If NOT, update using the
updater tool.
Does the HAP LED blink in regular
intervals (1 second ON/1 second OFF)?
Action
Yes
84] of the main PCB and
continue with the next procedure.
No
96].
To check if the correct spare part is installed
Prerequisite:
First perform all earlier main PCB checks, see
84].
1
Visit your local spare parts webbank.