![Daikin FTXP20-71L Service Manual Download Page 82](http://html1.mh-extra.com/html/daikin/ftxp20-71l/ftxp20-71l_service-manual_4200841082.webp)
3
|
Components
Service manual
82
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
b
b
a
b
a
Indoor unit main PCB
b
PCB support
3
Remove the indoor unit main PCB from the indoor unit.
4
To install the indoor unit main PCB, see
To install the indoor unit main PCB
1
Install the indoor unit main PCB in the correct location on the PCB supports.
b
b
a
b
a
Indoor unit main PCB
b
PCB support
2
Connect all connectors to the indoor unit main PCB.
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
159].
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
Is the problem solved?
Action
Yes
No further actions required.
No
78] of the indoor unit
main PCB and continue with the next
procedure.
Summary of Contents for FTXP20-71L
Page 190: ......
Page 191: ......
Page 192: ...ESIE18 01E 2023 01 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...