![Daikin FTXP20-71L Service Manual Download Page 121](http://html1.mh-extra.com/html/daikin/ftxp20-71l/ftxp20-71l_service-manual_4200841121.webp)
3
|
Components
Service manual
121
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
6
Remove the screw and remove the switch box from the indoor unit.
7
To install the switch box, see
111].
To install the switch box
1
install the switch box in the correct location on the indoor unit.
a a
b
c
d
e
a
Grouding wire screw
b
Heat exchanger thermistor
c
Indoor unit PCB
d
Switch box screw
e
Switch box
2
Route the connectors of the indoor unit fan motor, swing flap motor and
swing raster motor (if equipped) inside the switch box and connect them to
the indoor unit PCB.
3
Install and tighten the screw to secure the switch box.
4
Install the heat exchanger thermistor in its holder.
5
Connect the grounding wires to the heat exchanger using the screws.
6
Connect the power supply wiring to the power supply terminal X1M.
7
Install the power supply wiring bracket. Install and tighten the screw.
To re-install the front grille
1
Install the front grille and firmly engage the 3 upper hooks.
2
Install 2 screws (class 20~35) or 3 screws (class 50~71) back on the front grille.
3
Install the air filter and then mount the front panel.
To re-install the front panel
1
Attach the front panel. Align the shafts with the slots and push them all the
way in.
2
Summary of Contents for FTXP20-71L
Page 190: ......
Page 191: ......
Page 192: ...ESIE18 01E 2023 01 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...