![background image](http://html1.mh-extra.com/html/daikin/ftxj-m/ftxj-m_service-manual_4699040078.webp)
ESIE16-02K
|
Part 3. Repair
3.3. Unit specific repair procedures
Page 78
31/05/21
|
Version 1.1
RA R32 Split & multi split M-Series
Figure 3-14: Removing the compressor
1. Screw
6. Nut
2. Partition plate assembly
7. Compressor
3. Terminal cover
8. Putty
4. Compressor wiring
9. Dampers
5. Compressor pipe
10. Bushing
1
2
1
3
8
7
4
5
5
8
9
3
3
8
9