![background image](http://html1.mh-extra.com/html/daikin/ftxj-ab/ftxj-ab_operation-manual_2459441008.webp)
5 Operation
Operation manual
8
FTXJ-A(W)(S)(B)
Daikin room air conditioner
3P485919-15W – 2021.12
3
Press
to exit to the home screen or use EXIT screen to
return to “indoor unit setting menu”.
To connect using SSID and KEY number
1
Open the ONECTA app on your smart device and follow the
steps on the screen.
2
Connect your smart device to the same home network as the
unit.
3
Check if the connection was successful (refer to
wireless LAN connection status"
8]).
4
Press
to exit to the home screen or use EXIT screen to
return to “indoor unit setting menu”.
To confirm the wireless LAN connection status
1
Navigate to the status screen using
and
. Press
to
confirm.
Status screen
STATUS
2
Check the Daikin eye.
b
c
a
a
Daikin eye
b
Partly green
c
Red, orange or blue
Daikin eye colour alternates
between partly green and…
…then wireless adapter is…
Red
not connected
orange
running and ready to connect to
the home network via WPS
button; see
blue
connected to the home network:
▪ via SSID + KEY.
or
▪ via the WPS button on the
router.
3
Press
to exit to the home screen or use EXIT screen to
return to the indoor unit setting menu.
To reset the connection setting to the factory default
Reset the connection setting to the factory default in case you want
to:
▪ disconnect the wireless LAN and the communication device (e.g.
router) or smart device.
▪ repeat the setting if the connection was unsuccessful.
1
Navigate to the RESET screen using
and
. Press
to
confirm your selection.
Result:
The setting is reset to the factory default.
Reset screen
RESET
2
Press
to exit to the home screen or use EXIT screen to
return to the indoor unit setting menu.
To turn off the wireless LAN connection
1
Enter the wireless LAN connection setting menu and change
the setting to OFF using
and
. Press
to confirm your
selection.
Result:
The Daikin eye alternates between green and white.
Communication is OFF.
4.4.3
Vertical airflow function
This function helps with optimal airflow and temperature distribution
in heating operation mode. You can turn this function OFF in case
there is furniture or another object under the unit.
Vertical airflow OFF
Vertical airflow ON
To turn ON/OFF vertical airflow function
1
In the indoor unit setting menu, navigate to the vertical airflow
setting using
and
.
Vertical airflow function ON
Vertical airflow function OFF
2
Change the setting using
and
.
3
Press
to confirm your selection.
4
Press
again to return to the main menu or press
to
return to the home screen.
5
Operation
INFORMATION
The indoor unit is delivered with the wireless remote
control as the user interface. This manual describes only
operation with this user interface. If another user interface
is connected, refer to the operation manual of the
connected user interface.
5.1
Operation range
Use the system in the following temperature and humidity ranges for
safe and effective operation.
Cooling and
drying
(a)(b)
Heating
(a)
Outdoor temperature for
RXJ models
–10~50°C DB
–20~24°C DB
–21~18°C WB