background image

5 Operation

Operation manual

12

FTXJ-A(W)(S)(B)

Daikin room air conditioner

3P485919-15W – 2021.12

Intelligent eye active

Intelligent eye disabled

3

Press 

 to confirm your selection.

Result: 

Intelligent eye 

active:

 

 appears on the bottom of the

home screen.

Result: 

Intelligent  eye 

disabled:

 

  disappears  from  the

bottom of the home screen.

5.6

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo,
Comfort  airflow  and  Outdoor  unit  quiet  operation.  The  last
selected function takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

5.6.1

To start/stop Powerful operation

1

Press 

 to enter the powerful operation pop-up menu.

2

Press 

 or 

 and 

 to activate or disable the function.

Result: 

Powerful  operation 

active:

 

  appears  on  the  bottom

of the home screen.

Result: 

Powerful  operation 

disabled:

 

  disappears  from  the

bottom of the home screen.

Powerful operation active

Powerful operation disabled

INFORMATION

▪ Powerful  operation  can  be  set  only  when  the  unit  is

running; the 

 symbol on the screen indicates that the

function is currently prohibited.

▪ If  you  press 

  or  if  you  change  the  operation  mode,

operation  will  be  cancelled; 

  disappears  from  the

bottom of the home screen.

5.7

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

5.7.1

To start/stop Econo operation

1

Press 

  to  enter  the  main  menu  and  navigate  to  the  Econo

screen using 

 and 

.

2

Change the setting using 

 and 

.

Econo operation active

Econo operation disabled

3

Press 

 to confirm your selection.

Result: 

Econo  operation 

active:

 

  appears  on  the  bottom  of

the home screen.

Result: 

Econo  operation 

disabled:

 

  disappears  from  the

bottom of the home screen.

INFORMATION

▪ Econo  operation  can  be  set  only  when  the  unit  is

running;  the 

  symbol  on  the  screen  indicates  that

function is currently prohibited.

▪ If you press 

, change the operation mode to fan only

or  set  Powerful  operation,  Econo  operation  will  be

cancelled; 

 disappears from the bottom of the home

screen.

5.8

Outdoor unit quiet operation

Use  Outdoor  unit  quiet  operation  when  you  want  to  decrease  the
noise level of the outdoor unit. 

Example: 

At night.

INFORMATION

▪ Powerful and Outdoor unit quiet operation CANNOT be

used at the same time. The last selected function takes
priority.

▪ This  function  is  only  available  in  Automatic,  Cooling,

and Heating operation.

▪ Outdoor unit quiet operation limits the rotation speed of

the compressor. If the rotation speed of compressor is
already  low,  Outdoor  unit  quiet  operation  will  NOT
further reduce the compressor rotation speed.

5.8.1

To start/stop Outdoor unit quiet operation

1

Press 

  to  enter  the  outdoor  unit  quiet  operation  pop-up

menu.

Outdoor unit quiet operation

active

Outdoor unit quiet operation

disabled

2

Press 

 or 

 and 

 to activate or disable the function.

Result: 

Outdoor unit quiet 

active:

 

 appears on the bottom of

the home screen.

Result: 

Outdoor  unit  quiet 

disabled:

 

  disappears  from  the

bottom of the home screen.

Note: 

 remains on the home screen, even if you turn off the unit

using the wireless remote control or indoor unit ON/OFF switch.

Summary of Contents for FTXJ-AB

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: