background image

5 Operation

Operation manual

10

FTXJ-A(W)(S)(B)

Daikin room air conditioner

3P485919-15W – 2021.12

Setting

Description

Automatic

The indoor unit adjusts its fan speed
automatically according to the setpoint and
indoor temperature.

Indoor unit quiet

operation

For reduction of noise coming from the
indoor unit

(

Example: 

 at night)

INFORMATION

If the unit reaches the temperature setpoint:

▪ in cooling or automatic mode. Fan will stop operating.

▪ in heating mode. Fan will operate in low airflow rate.

5.3.1

To adjust the airflow rate

1

Press 

 to enter the airflow rate carousel menu. When 

 is

pressed repeatedly, the mode will change as follows:

INFORMATION

▪ In  the  carousel  menu,  you  can  also  navigate  in  both

directions using 

 and 

 or 

 and 

.

▪ The  carousel  menu  will  always  start  with  the  currently

active setting.

5.4

Airflow direction

The airflow direction is the direction in which the indoor unit blows its
air. It does so by moving horizontal blades (flaps) or vertical blades
(louvers).  Adjust  the  airflow  direction  as  desired  and  in  swing  or  in
fixed position.

Setting

Airflow direction

Vertical automatic swing Moves the horizontal blades (flaps) up

and down.

Horizontal automatic

swing

Moves the vertical blades (louvers) from
side to side.

3-D airflow direction

Moves alternately up and down and
from side to side

[—]

Stays in a fixed position.

CAUTION

ALWAYS  use  the  wireless  remote  control  or  other  user
interface  (if  applicable)  to  adjust  the  position  of  the  flaps
and louvers. When the flaps and louvers are swinging and
you move them forcibly by hand, the mechanism will break.

The  movable  range  of  the  flap  varies  according  to  the  operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.

Comfort airflow

The unit will automatically change the direction of the airflow to heat
up  or  cool  down  the  room  more  effectively.  Direct  airflow  from  the
unit will be less noticeable.

a

b

c

a

Flap position in cooling and dry operation

b

Flap position in heating operation (

vertical airflow OFF

)

c

Flap position in heating operation (

vertical airflow ON

)

In cooling and drying

The airflow direction will change to spread the
air along the ceiling.

Comfort airflow 

active

Comfort airflow 

disabled

In heating

The airflow direction will change to spread the
air along the floor.

If  the  Vertical  airflow  function  is  ON

:  The  unit  detects  the  room

and  floor  temperature  and  automatically  selects  1  of  the  3  airflow
directions (space warming, downward, vertical).

If the Vertical airflow function is OFF

: The unit will operate only in

downward airflow direction.

Space warming

airflow

Downward airflow

Vertical airflow

INFORMATION

If  you  want  to  deactivate  the  Vertical  airflow  function  (e.g.
in case there is furniture or another object under the unit),
refer  to 

"To  turn  ON/OFF  vertical  airflow  function"

  [

4

  8].  If

the  Vertical  airflow  function  is  deactivated,  the  airflow  will
be set to downward direction.

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If  the  vertical  automatic  swing  is  selected,  Comfort  airflow
operation will be cancelled.

1

Enter the main menu by pressing 

 and navigate to the airflow

direction setting menu using 

 and 

. Press 

 to enter the

menu.

Summary of Contents for FTXJ-AB

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: