background image

5 Operation

Operation manual

13

FTXJ-A(W)(S)(B)
Daikin room air conditioner
3P485919-15W – 2021.12

5.9

Flash Streamer (air cleaning)
operation

Streamer  generates  a  high-speed  electron  stream  with  a  high
oxidizing  power,  reducing  bad  odours.  Together  with  the  titanium
apatite deodorising filter and the air filters, this function cleans the air
in the room.

INFORMATION

▪ The  high-speed  electrons  are  generated  and  go  away

inside the unit to ensure safe operation.

▪ The Streamer discharge may generate a fizzing sound.

▪ If  the  airflow  becomes  weak,  the  Streamer  discharge

may stop temporarily to prevent ozone smell.

5.9.1

To start/stop Flash Streamer (air cleaning)
operation

1

Press 

 to enter the main menu. The Flash Streamer screen

is on the first position of the main menu.

2

Change the setting using 

 and 

.

Flash Streamer operation

active

Flash Streamer operation

disabled

3

Press 

 to confirm your selection.

Result: 

Flash  streamer  operation 

active:

 

  appears  on  the

bottom of the home screen.

Result: 

Flash  streamer  operation 

disabled:

 

  disappears

from the bottom of the home screen.

5.10

Clock and timer setting

1

Enter the main menu by pressing 

 and navigate to the clock

and timer setting menu using 

 and 

. Press 

 to enter the

menu.

Clock and timer setting menu

2

In  this  menu,  perform  the  following  clock  and  timer  setting.

Then press 

 to return to the main menu or press 

 to exit

to the home screen.

5.10.1

The clock setting

If  the  indoor  unit's  internal  clock  is  NOT  set  to  the  correct  time,  the
ON  timer,  OFF  timer  and  weekly  timer  will  NOT  operate  correctly.
The clock must be set again:

▪ After a circuit breaker has turned the unit OFF.

▪ After a power failure.

▪ After replacing batteries in the wireless remote control.

To set the clock

1

In  the  clock  and  timer  setting  menu,  navigate  to  the  clock

setting screen using 

 and 

. Enter the setting using 

.

Clock setting

 (displays current clock setting)

TUE

12:25

Note: 

If the time was not yet set, you will first enter the clock setting.

No other timer setting can be done until the clock is set.

2

Change the day of the week using 

 and 

.

Day of the week setting

MON

0:00

3

Go to the hours setting using 

.

Hours setting

TUE

0:00

4

Change the hour using 

 and 

 (24-hour format).

5

Go to the minutes setting using 

.

Minutes setting

TUE

12:00

6

Change the minutes using 

 and 

.

5.10.2

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the wireless remote control,

the  remote  control  keeps  the  time  setting  for  the  ON/
OFF timer, but the timer is cancelled.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"To set the clock"

 [

4

 13].

To start/stop OFF timer operation

1

In the clock and timer setting menu, navigate to the OFF timer

screen using 

 and 

.

OFF timer disabled

OFF timer set to 7:00

14:00

7:00

2

Press 

 to enter the OFF timer setting menu.

Summary of Contents for FTXJ-AB

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: