Outdoor Unit
Si04-402A
152
Removal Procedure
2. Outdoor Unit
2.1
Removal of Panels and Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Features
Take care not to cut your
finger by the fins of the heat
exchanger.
The stop valve cover is
united with the shelter.
When reassembling, make
sure to fit the 5 hooks.
1
Loosen the screw of the
stop valve cover.
Pull down the stop
valve cover and remove
it.