background image

Table of contents

Operation manual

2

FTXF20~42D5V1B

Daikin room air conditioner

3P520336-14P – 2021.09

Table of contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 User safety instructions

2

2.1

General......................................................................................

2

2.2

Instructions for safe operation ...................................................

3

3 About the system

4

3.1

Indoor unit .................................................................................

4

3.2

About the user interface ............................................................

5

3.2.1

Components: User interface .......................................

5

3.2.2

Status: User interface LCD .........................................

5

3.2.3

To operate the user interface......................................

6

4 Before operation

6

4.1

To mount the user interface holder ...........................................

6

4.2

To insert the batteries................................................................

6

4.3

To turn on the power supply......................................................

6

5 Operation

6

5.1

Operation range ........................................................................

6

5.2

When to use which feature........................................................

6

5.3

Operation mode and temperature setpoint................................

7

5.3.1

To start/stop operation mode and to set the
temperature.................................................................

7

5.3.2

Airflow rate ..................................................................

7

5.3.3

Airflow direction...........................................................

8

5.3.4

Comfort airflow operation............................................

8

5.3.5

Powerful operation ......................................................

8

5.3.6

Econo operation..........................................................

9

5.3.7

OFF/ON timer operation .............................................

9

6 Energy saving and optimum operation

9

7 Maintenance and service

10

7.1

Overview: Maintenance and service .........................................

10

7.2

To clean the indoor unit and user interface ...............................

11

7.3

To clean the front panel.............................................................

11

7.4

About the air filters ....................................................................

11

7.5

To clean the air filters ................................................................

11

7.6

To take following items into account before a long idle period..

11

8 Troubleshooting

11

8.1

Symptoms that are NOT system malfunctions ..........................

12

8.1.1

Symptom: A sound like water flowing is heard ........... 12

8.1.2

Symptom: A blowing sound is heard........................... 12

8.1.3

Symptom: A ticking sound is heard............................. 12

8.1.4

Symptom: A whistling sound is heard ......................... 12

8.1.5

Symptom: A clicking sound during operation or idle
time is heard ............................................................... 12

8.1.6

Symptom: A clapping sound is heard ......................... 12

8.1.7

Symptom: The outdoor fan rotates while the air
conditioner is not in operation ..................................... 12

8.2

Solving problems based on error codes....................................

12

9 Disposal

13

1

About the documentation

1.1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If NOT, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

2

User safety instructions

Always observe the following safety instructions and regulations.

2.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction

Summary of Contents for FTXF20D5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20D5V1B FTXF25D5V1B FTXF35D5V1B FTXF42D5V1B...

Page 2: ...onditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Please Read the doc...

Page 3: ...etal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are disposed of...

Page 4: ...s OFF Otherwise an electrical shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...e is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting...

Page 8: ...louvers should be facing away from the wall Efficiency will drop if a wall blocks the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provi...

Page 9: ...tart Result is displayed on the LCD and the timer lamp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 9 hours 2 Press to stop Result d...

Page 10: ...ulate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit...

Page 11: ...own 2 Pull out the air filters 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes 5 Install all filters back in their origina...

Page 12: ...when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is generated when an external device sucks air out of the room e g exhaust fan extra...

Page 13: ...e thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise Inverter instantaneous overcurre...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 14P 2021 09 Copyright 2...

Reviews: