background image

3 About the system

Operation manual

5

FTXF20~42D5V1B
Daikin room air conditioner
3P520336-14P – 2021.09

a

c d

ON/OFF

f

g

l

h

i

k

j

e

b

a

Air inlet

b

Air outlet

c

Flap (horizontal blade)

d

Louvers (vertical blades)

e

Front panel

f

Model name plate

g

Room temperature sensor

h

Signal receiver

i

Operation indicator (green)

j

Timer lamp (orange)

k

Indoor unit ON/OFF switch

l

Air filter

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  user  interface  signals  operate  other

appliances, move the other appliances, or contact your installer.

Curtains.

 Make sure that the signal between the unit and the user

interface is NOT blocked by curtains or other objects.

NOTICE

▪ Do NOT drop the user interface.

▪ Do NOT let the user interface get wet.

3.2.1

Components: User interface

b

d

c

f

h

e

m

l

k

i

j

a

g

a

Signal transmitter

b

LCD display

c

ON/OFF button

d

Fan setting button

e

Temperature adjustment button

f

Swing button

g

Timer cancel button

h

ON timer button

i

OFF timer button

j

Comfort airflow button

k

Econo button

l

Mode selector button

m

Powerful button

3.2.2

Status: User interface LCD

Icon

Description

Operation mode = Automatic

Operation mode = Drying

Operation mode = Heating

Operation mode = Cooling

Operation mode = Fan only

Powerful operation is active

Econo operation is active

Operation is active

The indoor unit receives a signal
from the user interface

Current temperature setting

Airflow rate = Automatic

Airflow rate = Indoor unit quiet

Summary of Contents for FTXF20D5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20D5V1B FTXF25D5V1B FTXF35D5V1B FTXF42D5V1B...

Page 2: ...onditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Please Read the doc...

Page 3: ...etal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are disposed of...

Page 4: ...s OFF Otherwise an electrical shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...e is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting...

Page 8: ...louvers should be facing away from the wall Efficiency will drop if a wall blocks the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provi...

Page 9: ...tart Result is displayed on the LCD and the timer lamp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 9 hours 2 Press to stop Result d...

Page 10: ...ulate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit...

Page 11: ...own 2 Pull out the air filters 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes 5 Install all filters back in their origina...

Page 12: ...when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is generated when an external device sucks air out of the room e g exhaust fan extra...

Page 13: ...e thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise Inverter instantaneous overcurre...

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P520336 14P 2021 09 Copyright 2...

Reviews: