background image

8 Troubleshooting

Operation manual

11

FTXF20~42D5V1B
Daikin room air conditioner
3P520336-14P – 2021.09

7.2

To clean the indoor unit and user
interface

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner,  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

▪ As an end user, you may NEVER clean inside parts of

the unit by yourself; this work must be performed by a
qualified service person. Contact your dealer.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  OFF  or  pull  out  the  supply  cord.  Otherwise,  an
electrical shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

7.4

About the air filters

Operating the unit with dirty filters means that the filter:

▪ CANNOT deodorise the air,

▪ CANNOT clean the air,

▪ poor heating/cooling,

▪ causes odour.

7.5

To clean the air filters

1

Push the tab at the centre of each air filter, then pull it down.

2

Pull out the air filters.

2

1

3

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

4

Soak in lukewarm water for about 10 to 15 minutes.

5

Install all filters back in their original positions.

INFORMATION

▪ If the dust does NOT come off easily, wash them with a

neutral detergent diluted in lukewarm water. Dry the air
filters in the shade.

▪ It  is  recommended  to  clean  the  air  filters  every  2

weeks.

7.6

To take following items into
account before a long idle period

Operate the unit in 

fan only

 mode for several hours to dry the inside

of the unit.

1

Press 

 and select fan only operation.

2

Press 

 to start operation.

3

After operation stops, turn the breaker off.

4

Clean the air filters and replace them in their original position.

5

Remove the batteries from the user interface.

INFORMATION

It  is  recommended  to  have  periodical  maintenance
performed  by  a  specialist.  For  specialist  maintenance,
contact  your  dealer.  Maintenance  costs  shall  be  borne  by
the customer.

In  certain  operating  conditions  the  inside  of  the  unit  may
get dirty after several seasons of use. This results in poor
performance.

8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

Summary of Contents for FTXF20D5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20D5V1B FTXF25D5V1B FTXF35D5V1B FTXF42D5V1B...

Page 2: ...onditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Please Read the doc...

Page 3: ...etal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are disposed of...

Page 4: ...s OFF Otherwise an electrical shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...e is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting...

Page 8: ...louvers should be facing away from the wall Efficiency will drop if a wall blocks the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provi...

Page 9: ...tart Result is displayed on the LCD and the timer lamp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 9 hours 2 Press to stop Result d...

Page 10: ...ulate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit...

Page 11: ...own 2 Pull out the air filters 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes 5 Install all filters back in their origina...