Feature

Tasks

 Airflow rate

To adjust the amount of air blown into
the room.

To run more quietly.

Advanced features

 Econo

To use the system when you are also
using other power-consuming
appliances.

To save energy.

 Comfort

To provide a comfortable airflow that
does NOT come in direct contact with
people.

 Powerful

To cool down or heat up the room
quickly.

 ON timer + 

 OFF

timer

To automatically turn ON or OFF the
system.

5.3

Operation mode and temperature
setpoint

When.

  Adjust  the  system  operation  mode  and  set  the  temperature

when you want to:

▪ Heat up or cool down a room

▪ Blow air in a room without heating or cooling

▪ Decrease the humidity in a room

What.

  The  system  operates  differently,  depending  on  the  user

selection.

Setting

Description

 Automatic

The system cools down or heats up a
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.

 Drying

The system decreases the humidity in a
room.

 Heating

The system heats up a room to the
temperature setpoint.

 Cooling

The system cools down a room to the
temperature setpoint.

 Fan

The system only controls the airflow
(airflow rate and airflow direction).

The system does NOT control the
temperature.

Additional info:

Outside  temperature.

  The  system's  cooling  or  heating  effect

decreases when the outside temperature is too high or too low.

Defrost operation.

 During heating operation, frost might occur on

the  outdoor  unit  and  decrease  the  heating  capacity.  In  that  case,
the  system  automatically  switches  to  defrosting  operation  to
remove  the  frost.  During  defrosting  operation,  hot  air  is  NOT
blown from the indoor unit.

5.3.1

To start/stop operation mode and to set
the temperature

: Unit is operating.

: Operation mode = Automatic

: Operation mode = Drying

: Operation mode = Heating

: Operation mode = Cooling

: Operation mode = Fan only

: Shows the set temperature.

1

Press 

 one or more times to select the operation mode.

Result: 

The mode will be set in the following sequence:

2

Press 

 to 

start

 operation.

Result: 

 is displayed on the LCD.

Result: 

The operation lamp lights up.

3

Press   or   on the 

 button one or more times to lower or

raise the 

temperature

.

Note:

  When  using  drying  or  fan  only  mode,  you  cannot  adjust  the

temperature.

4

Press 

 to 

stop

 operation.

Result: 

 disappears from the LCD.

Result: 

The operation lamp goes off.

5.3.2

Airflow rate

INFORMATION

▪ When  using  drying  operation  mode,  you  CANNOT

adjust the airflow rate setting.

▪ The  airflow  rate  in  heating  mode  will  lower  to  avoid

generating  cold  airflow.  When  temperature  of  the
airflow  rise,  operation  will  continue  at  the  set  airflow
rate.

1

Press 

 to choose:

5 airflow rate levels, from "

" to "

"

Automatic airflow rate operation

Indoor unit quiet operation. When the airflow rate is

set to "

", the noise from the unit will be reduced.

INFORMATION

If the unit reach the temperature setpoint:

▪ in cooling or automatic mode. Fan will stop operating.

▪ in heating mode. Fan will operate in low airflow rate.

Summary of Contents for FTXF20D5V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20D5V1B FTXF25D5V1B FTXF35D5V1B FTXF42D5V1B...

Page 2: ...onditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 1 About the documentation 1 1 About this document Thank you for purchasing this product Please Read the doc...

Page 3: ...etal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised treatment facility for reuse By ensuring waste batteries are disposed of...

Page 4: ...s OFF Otherwise an electrical shock and injury may result CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with...

Page 5: ...abled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your install...

Page 6: ...batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position...

Page 7: ...e is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting...

Page 8: ...louvers should be facing away from the wall Efficiency will drop if a wall blocks the air 5 3 4 Comfort airflow operation This operation can be used in heating or cooling operation mode It will provi...

Page 9: ...tart Result is displayed on the LCD and the timer lamp lights up INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 9 hours 2 Press to stop Result d...

Page 10: ...ulate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING The refrigerant inside the unit...

Page 11: ...own 2 Pull out the air filters 2 1 3 Wash the air filters with water or clean them with a vacuum cleaner 4 Soak in lukewarm water for about 10 to 15 minutes 5 Install all filters back in their origina...

Page 12: ...when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is generated when an external device sucks air out of the room e g exhaust fan extra...

Page 13: ...e thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise Inverter instantaneous overcurre...

Page 14: ......

Page 15: ......