Indoor Unit Installation

2.

Boring a wall hole and installing wall embedded pipe

• For walls containing metal frame or metal board, be sure to use a wall 

embedded pipe and wall cover in the feed-through hole to prevent possible 
heat, electrical shock, or fire.

• Be sure to caulk the gaps around the pipes with caulking material to prevent 

water leakage.

1) Bore a feed-through hole of 2-9/16 inch (65mm) in the wall so it has a 

down slope toward the outside.

2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole 

gap with putty.

3.

Installing indoor unit

• In the case of bending or curing refrigerant pipes, keep the following 

precautions in mind. 
Abnormal sound may be generated if improper work is conducted.

1) Do not strongly press the refrigerant pipes onto the bottom frame.
2) Do not strongly press the refrigerant pipes on the front grille, either.

3-1. Right-side, right-back, or right-bottom piping 

1) Attach the drain hose to the underside of the refrigerant pipes with 

an adhesive vinyl tape.

2) Wrap the refrigerant pipes and drain hose together with insulation 

tape.

3) Pass the drain hose and refrigerant pipes through the wall hole, then 

set the indoor unit on the mounting plate hooks by using the 

 

markings at the top of the indoor unit as a guide.

4) Open the front panel, then open the service lid.
5) Pass the inter-unit wiring from the outdoor unit through the 

feed-through wall hole and then through the back of the indoor 
unit. Pull them through the front side.  Bend the ends of tie 
wires upward for easier work in advance. (If the inter-unit wiring 
ends are to be stripped first, bundle wire ends with adhesive 
tape.)

6) Press the bottom frame of the indoor unit with both hands to set 

it on the mounting plate hooks. Make sure the wires do not 
catch on the edge of the indoor unit.

Inside

Outside

Caulking

Wall embedded pipe 
(field supply)

Wall hole cover
(field supply)

Wall embedded pipe 
(field supply)

φ

2-9/16” 

(

φ

65mm)

1)

2)

Right-bottom 
piping

Right-side piping

Right-back piping

Bind coolant pipe 
and drain hose 
together with 
insulating tape.

Remove pipe port cover 
here for right-side piping.

Remove pipe port cover 
here for right-bottom piping.

Mounting plate

A

When stripping the 
ends of inter-unit wiring in 
advance, bind right ends 
of wires with insulating tape.

Hang indoor unit’s hook here.

Inter-unit wiring

Mounting plate

A

01_EN_3P253189-1E.fm  Page 6  Friday, August 20, 2010  9:36 AM

Summary of Contents for FTKN09JEVJU

Page 1: ...DITIONER English Fran ais Espa ol Installation manual Manuel d installation Manual de instalaci n MODELS FTXS09JEVJU FTXN09JEVJU FTXS12JEVJU FTXN12JEVJU FTKS09JEVJU FTKN09JEVJU FTKS12JEVJU FTKN12JEVJU...

Page 2: ...ing rods because lightning strikes could cause a severe shock hazard resulting in severe injury or death and to gas pipes because a gas leak could result in an explosion which could lead to severe inj...

Page 3: ...ttach the refrigerant piping securely before running the compressor If the compressor is not attached and the stop valve is open during pump down air will be sucked in when the compressor is run causi...

Page 4: ...ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firml...

Page 5: ...e the front grille How to remove the indoor unit Push up the marked area at the lower part of the front grille to release the claws If it is difficult to release remove the front grille The mounting p...

Page 6: ...pipe port cover can be kept in the mounting plate pocket Removed pipe port cover A Mounting plate Use tape measure as shown Position the end of a tape measure at Liquid pipe end Gas pipe end Through t...

Page 7: ...ther with insulation tape 3 Pass the drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as...

Page 8: ...the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tighten with included insulation fixing screw Forgetting to tighten this may cause water leakages How to rep...

Page 9: ...oor unit Doing so may cause electric shock or fire 5 When connecting to a wired remote controller If work space is available on the right side of the indoor unit the work can be performed with the ele...

Page 10: ...box 2 Route the connection cord as shown in Figure 3 5 8 Install the indoor unit electrical component box in its original position 1 Install the louver 2 Install the electrical component box 1 screw...

Page 11: ...from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations Only use parts which are delivered with the unit Never inst...

Page 12: ...on materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and...

Page 13: ...ly The air conditioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power...

Page 14: ...1010 HT 3P253189 1E M09B108C Two dimensional bar code is a code for manufacturing 66162757 00_CV_3P253189 1E fm Page 2 Friday August 20 2010 9 33 AM...

Reviews: