Preparation before Installation

1.

Removing and installing front panel

• Removal  method

Hook fingers on the tabs on the left and right of the main body, and open 
until the panel stops. Slide the front panel sideways to disengage the 
rotating shaft. Then pull the front panel toward you to remove it.

• Installation method

Align the tabs of the front panel with the grooves, and push all the way in. 
Then close slowly. Push the center of the lower surface of the panel firmly 
to engage the tabs.

2.

Removing and installing front grille

• Removal  method

1) Remove front panel to remove the air filter.
2) Remove 2 screws from the front grille.

3) In front of the 

{{{

 mark of the front grille, there are 3 upper hooks. 

Lightly pull the front grille toward you with one hand, and push down on 
the hooks with the fingers of your other hand.

When there is no work space because the unit is close to ceiling

CAUTION

• Be sure to wear protection gloves.

Place both hands under the center of the front grille, and while pushing up, pull it toward you.

• Installation method

1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 2 screws of the front grille.
3) Install the air filter and then mount the front panel.

3.

How to set the different addresses

When two indoor units are installed in one room, the two wireless remote controllers 
can be set for different addresses.

1) In the same way as when connecting to an HA system, remove the metal plate 

electrical wiring cover.

2) Cut the address jumper (JA) on the printed circuit board.
3) Cut the address jumper (J4) in the remote controller.

Push the rotating 
shaft of the front 
panel into the groove.

¡¡¡

 mark area 

(3 locations)

Upper hook

Lightly pull the front 
grille toward you with 
one hand, and push 
down on the hooks with 
the fingers of your other 
hand. (3 locations)

Push
down.

Upper hook

1) Push up.

2) Pull toward you.

ADDRESS

EXIST
 CUT

1
2

JA

JA

ADDRESS

J4

EXIST

1

 CUT

2

J4

01_EN_3P253189-1E.fm  Page 3  Friday, August 20, 2010  9:36 AM

Summary of Contents for FTKN09JEVJU

Page 1: ...DITIONER English Fran ais Espa ol Installation manual Manuel d installation Manual de instalaci n MODELS FTXS09JEVJU FTXN09JEVJU FTXS12JEVJU FTXN12JEVJU FTKS09JEVJU FTKN09JEVJU FTKS12JEVJU FTKN12JEVJU...

Page 2: ...ing rods because lightning strikes could cause a severe shock hazard resulting in severe injury or death and to gas pipes because a gas leak could result in an explosion which could lead to severe inj...

Page 3: ...ttach the refrigerant piping securely before running the compressor If the compressor is not attached and the stop valve is open during pump down air will be sucked in when the compressor is run causi...

Page 4: ...ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firml...

Page 5: ...e the front grille How to remove the indoor unit Push up the marked area at the lower part of the front grille to release the claws If it is difficult to release remove the front grille The mounting p...

Page 6: ...pipe port cover can be kept in the mounting plate pocket Removed pipe port cover A Mounting plate Use tape measure as shown Position the end of a tape measure at Liquid pipe end Gas pipe end Through t...

Page 7: ...ther with insulation tape 3 Pass the drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as...

Page 8: ...the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tighten with included insulation fixing screw Forgetting to tighten this may cause water leakages How to rep...

Page 9: ...oor unit Doing so may cause electric shock or fire 5 When connecting to a wired remote controller If work space is available on the right side of the indoor unit the work can be performed with the ele...

Page 10: ...box 2 Route the connection cord as shown in Figure 3 5 8 Install the indoor unit electrical component box in its original position 1 Install the louver 2 Install the electrical component box 1 screw...

Page 11: ...from getting into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations Only use parts which are delivered with the unit Never inst...

Page 12: ...on materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and...

Page 13: ...ly The air conditioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power...

Page 14: ...1010 HT 3P253189 1E M09B108C Two dimensional bar code is a code for manufacturing 66162757 00_CV_3P253189 1E fm Page 2 Friday August 20 2010 9 33 AM...

Reviews: