![background image](http://html1.mh-extra.com/html/daikin/ftkm28pvmk/ftkm28pvmk_service-manual_2459350009.webp)
Si041352EB
Electrical Box
Removal Procedure
7
4
Pull out the indoor heat
exchanger thermistor.
The position of the indoor
heat exchanger thermistor
varies by the model.
Be careful not to lose the clip
of the thermistor.
Cut the clamp if any.
5
6
Remove the 4 screws
on the terminal board
and disconnect the
connecting wire.
Remove the screw and
remove the wire fixture.
7
Disconnect the
connector [S1] and
release the harness
from the hook.
[S1]: fan motor
8
Release the ferrite
core.
Step
Procedure
Points
1 2
3
Indoor heat exchanger thermistor
(R22045)
Clip
(R11268)
(R22132)
Clamp
1 2
3
(R18715)
Terminal board
Wire
fixture
Connecting wire
1 2
3
(R18716)
[S1]
Hook
(R9501)
Ferrite core