![background image](http://html1.mh-extra.com/html/daikin/ftkm28pvmk/ftkm28pvmk_service-manual_2459350019.webp)
Si041352EB
Swing Motors
Removal Procedure
17
6. Swing Motors
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Caution
When reassembling, do not confuse the installing order of the 2 motors for horizontal
blades and the colors of the connectors.
If you set the connectors or motors opposite, the horizontal blades do not move
smoothly or noise may be heard.
Step
Procedure
Points
1. Remove the swing motors
for horizontal blades.
1
Release the interlock
rod.
2
Pull out the drain hose,
then remove the swing
motor unit.
3
Remove the screw at
the center.
(R9546)
Interlock rod
(R13579)
Drain hose
Swing motor
unit
(R9548)