![background image](http://html1.mh-extra.com/html/daikin/ftkm28pvmk/ftkm28pvmk_service-manual_2459350013.webp)
Si041352EB
PCBs
Removal Procedure
11
2. Remove the
INTELLIGENT EYE
sensor PCB.
Some models do not have
the INTELLIGENT EYE
sensor PCB.
1
Unfasten the 4 hooks
and remove the
INTELLIGENT EYE
sensor ASSY.
2
Remove the sensor
from the shield plate.
When reassembling, set the
sensor at the position where
it clicks. Otherwise, the
sensor is not completely set.
3
4
5
Remove the shield
plate by unfastening the
2 hooks.
Disconnect the
connector [S36].
Remove the
INTELLIGENT EYE
sensor PCB.
[S36]: to control PCB
3. Remove the display PCB.
1
Unfasten the 4 hooks
and remove the display
PCB.
Step
Procedure
Points
(R9523)
Hook
Hook
INTELLIGENT EYE
sensor ASSY
(R9525)
Sensor
Shield plate
(R18892)
Shield plate (rear)
Hook
INTELLIGENT EYE
sensor PCB
[S36]
(R9528)
Display PCB