Electrical Box
Si041352EB
6
Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the screw.
The shape of the drip proof
plate varies by the model.
2
Remove the drip proof
plate from the indoor
heat exchanger.
When reassembling, fit the
hook to the indoor heat
exchanger.
3
Remove the screw and
release the earth /
ground wire.
1 2
3
(R9494)
Drip proof plate
(R9496)
(R9495)
1 2
3
(R18976)
Earth / ground wire