 WARNING

!

 CAUTION

Installation and maintenance should be performed by 
qualified persons who are familiar with local code and 
regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the 
national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that 
of the name plate before commencing wiring work according 
to the wiring diagram.
The unit must be GROUNDED to prevent possible hazard 
due to insulation failure.
All electrical wiring must not touch the water piping or any 
moving parts of the fan motors.
Confirm that the unit has been switched OFF before 
installing or servicing the unit.
Risk of electric shock, can cause injury or death. Disconnect 
all remain electric power supplies before servicing.
DO NOT pull out the power cord when the power is ON. 
This may cause serious electrical shocks which may result 
in the fire hazards.
Keep the indoor and outdoor units, power cable and 
transmission wiring, at least 1m from TVs and radios, to 
prevent distorted pictures and static. {Depending on the 
type and source of the electrical waves, static may be heard 
even when more than 1m away}.

Please take note of the following important points when 
installing.

Do not install the unit where leakage of flammable 
gas may occur.

 

If gas leaks and accumulates around the unit, it may 
cause fire ignition.

Ensure that drainage piping is connected properly.

 

If the drainage piping is not connected properly, it may 
cause water leakage which will dampen the furniture.

Do not overcharge the unit.

 

This unit is factory pre-charged. Overcharge will 
cause over-current or damage to the compressor.

Ensure that the unit’s panel is closed after service or 
installation.

 

  Un

secured panels will cause the unit to operate noi

sily.

Sharp edges and coil surfaces are potential locations 
which may cause injury hazards. Avoid from being in 
contact with these places.
Before turning off the power supply set the remote 
controller’s ON/OFF switch to the “OFF” position to prevent 
the nuisance tripping of the unit. 

If this is not done, the unit’s 

fans will start turning automatically when power resumes, posing 
a hazard to service personnel or the user.

Do not install the units at or near doorway.
Do not operate any heating apparatus too close to the air 
conditioner unit or use in room where mineral oil, oil vapour 
or oil steam exist, this may cause plastic part to melt or 
deform as a result of excessive heat or chemical reaction.
When the unit is used in kitchen, keep flour away from 
going into suction of the unit.
This unit is not suitable for factory used where cutting oil 
mist or iron powder exist or voltage fluctuates greatly.
Do not install the units at area like hot spring or oil 
refinery plant where sulphide gas exists.
Ensure the color of wires of the outdoor unit and the 
terminal markings are same to the indoors respectively.
IMPORTANT : DO NOT INSTALL OR USE THE AIR 
CONDITIONER UNIT IN A LAUNDRY ROOM.
Don’t use joined and twisted wires for incoming power 
supply.
The equipment is not intended for use in a potentially 
explosive atmosphere.


SAFETY PRECAUTIONS

INSTALLATION MANUAL

NOTICE

Disposal requirement

Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed 
with unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil 
and of other parts must be done by a qualified installer in accordance with relevant local and national legislation.
Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product 
is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please 
contact the installer or local authority for more information.
Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national 
legislation.

This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit.
Special adjustment may be necessary to suit local requirement.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use 
by lay persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

1-EN-IM WMJ-1111(0)Daikin.indd   3

11/29/11   2:04:42 PM

Summary of Contents for FTD20JEV1K

Page 1: ...INSTALLATION MANUAL MODELS FTD20JEV1K RD20JEV1K FTD25JEV1K RD25JEV1K R22 SPLIT SERIES English Installation Manual R22 Split Series IM WMJ 1111 0 DAIKIN Part No R08019033301...

Page 2: ......

Page 3: ...E TERMINAL BLOCK WITH EARTH TERMINAL All dimensions are in mm Original Instruction OUTLINE AND DIMENSIONS D B G H J L M A K F I G F E Through the wall hole 65mm Drain hose position Liquid pipe end Gas...

Page 4: ...mm Outdoor Unit Dimension Model A B C D E F G H I J K L M N O RD20JEV1K 855 628 328 520 181 44 93 149 101 113 603 126 164 17 34 RD25JEV1K 855 730 328 520 182 44 93 149 101 113 603 126 164 17 34 Dimen...

Page 5: ...useinroomwheremineraloil oilvapour or oil steam exist this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction When the unit is used in kitchen keep flour away...

Page 6: ...the smooth air flow Please follow the installation clearances shown in the figure Select the coolest possible place where intake air temperature is not greater than the outside air temperature please...

Page 7: ...to the required position in order to align it with the holes For the side and bottom hold the bottom of the piping and then position it to the required direction see figure The condensation drain hose...

Page 8: ...indoor unit with the upper edge of the installation plate Ensure that the hooks are properly seated on the installation plate by moving it to the left and right How To Attach The Indoor Unit Hook the...

Page 9: ...iquid Pipe Size mm in 6 35 1 4 9 52 3 8 L E Remark The refrigerant pre charged in the outdoor unit is for piping length up to 7 5m Be sure to add the proper amount of additional refrigerant Failure to...

Page 10: ...cause gas leak Insert the flare nuts mounted on the connection parts of both the indoor unit and outdoor unit into the copper pipes The exact length of pipe protruding from the top surface of the swa...

Page 11: ...d All wires must not touch the refrigerant piping compressor or any moving parts of the fan motor The connecting wires between the indoor unit and the outdoor unit must be clamped on the wire clamps T...

Page 12: ...vacuum pump Evacuate for approximately 30 minutes The evacuation time varies with different vacuum pump capacity Confirm that the charging gauge needle has moved towards 760mmHg Caution If the gauge...

Page 13: ...Indicator Lights for Cooling Unit IR Receiver Cooling Unit The table shows the LED indicator lights for the air conditioner unit under normal operation and fault conditions The LED indicator lights ar...

Page 14: ...e Room air sensor contact Loose Short Call your dealer Blink E1 3 times Outdoor coil sensor open Call your dealer Blink E3 2 times Indoor coil sensor open Call your dealer Blink E2 1 time Compressor o...

Page 15: ...occur on the louver thus resulting in drippings Frost Prevention When the air lter is dirty the evaporating temperature will decrease and eventually cause frosting If the evaporating temperature reach...

Page 16: ...e old Bio Filter as nonflammable garbage after use Operation with dirty filters 1 cannot deodorize the air 3 results in poor heating or cooling 2 cannot clean the air 4 may cause odour To order Bio Fi...

Page 17: ...eft and pull it to the front side to remove it 2 Attach the front panel Align the right and left rotating shafts of the front panel with the grooves and push them all the way in Gently close the front...

Page 18: ...been set incorrectly If the fault persist after all these verifications please contact the air conditioner unit installer The air flow is too low 3 The air filter is dirty The doors or windows are ope...

Page 19: ......

Page 20: ...fication and design contain herein at any time without prior notification Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Malays...

Reviews: