background image

 

Installation and operation manual

1

FMDQ50~125A7V3B

Air conditioning system

4PW47630-1

C

ONTENTS

Page

Before installation.............................................................................. 1

Important information regarding the refrigerant used........................ 2

Selecting installation site................................................................... 2

Preparations before installation......................................................... 2

Indoor unit installation ....................................................................... 3

Refrigerant piping work ..................................................................... 4

Drain piping work .............................................................................. 4

Electric wiring work ........................................................................... 5

Wiring example and how to set the remote controller ....................... 6

Wiring example ................................................................................. 6

Field setting....................................................................................... 7

Installation of the decoration panel ................................................... 8

Test operation.................................................................................... 8

Maintenance...................................................................................... 8

Disposal requirements ...................................................................... 9

Wiring diagram ................................................................................ 10

B

EFORE

 

INSTALLATION

Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.

Refer to the installation manual of the outdoor unit for items not
described in this manual.

Caution concerning refrigerant series R410A:
The connectable outdoor units must be designed exclusively for
R410A.

Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.

Precautions

Do not install or operate the unit in rooms mentioned below.
-

Places with mineral oil, or filled with oil vapour or spray like in 
kitchens. (Plastic parts may deteriorate.)

-

Where corrosive gas like sulphurous gas exists. (Copper 
tubing and brazed spots may corrode.)

-

Where volatile flammable gas like thinner or gasoline is used.

-

Where machines generating electromagnetic waves exist. 
(Control system may malfunction.)

-

Where the air contains high levels of salt such as air near the 
ocean and where voltage fluctuates a lot (e.g. in factories). 
Also in vehicles or vessels.

Do not install accessories on the casing directly. Drilling holes in
the casing may damage electrical wires and consequently cause
fire.

Accessories

Check if the following accessories are included with your unit.

Screws for fixing panels are attached to the air inlet panel.

Optional accessories

There are two types of remote controllers: wired and wireless.
Select a remote controller according to customer request and
install in an appropriate place.
Refer to catalogues and technical literature for selecting a
suitable remote controller.

When installing bottom suction: air inlet panel and canvas
connection for the air inlet panel.

FMDQ50A7V3B

FMDQ100A7V3B

FMDQ60A7V3B

FMDQ125A7V3B

FMDQ71A7V3B

Air conditioning system

Installation and

operation manual

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

Metal clamp

1 piece

Drain hose

1 piece

Washer for 

hanging bracket

8 pieces

Insulation for fitting

1 each

Screws for duct flanges

1 set

for gas pipe

for liquid pipe

16 pieces

Other: installation and operation manual, fuse

Summary of Contents for FMDQ50A7V3B

Page 1: ...INSTALLATION AND OPERATION MANUAL FMDQ50A7V3B FMDQ60A7V3B FMDQ71A7V3B FMDQ100A7V3B FMDQ125A7V3B Air conditioning system...

Page 2: ...2 5 6 7 4 3 4 4 1 3 2 4 5 5 5 2 1 2 3 6a 6a 2 3 1 4 680 85 6b 6b 1 3 2 4 6 5 50 200 45 680 6c 6c 1 5 2 3 7 4 680 65 3 3 1 4 3 4 2 800 630 B A 145 7c 7c 4 2 2 3 1 460 180 350 A 8 8 1 1 5m 0 625mm 2 6...

Page 3: ...12 gitt i henhold til bestemmelsene i 13 noudattaen m r yksi 14 za dodr en ustanoven p edpisu 15 prema odredbama 16 k veti a z 17 zgodnie z postanowieniami Dyrektyw 18 n urma prevederilor 19 ob upo te...

Page 4: ...volatile flammable gas like thinner or gasoline is used Where machines generating electromagnetic waves exist Control system may malfunction Where the air contains high levels of salt such as air near...

Page 5: ...age interference and noise in those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if 1 meter is kept 2 Use suspension bolts f...

Page 6: ...ides of the hanger bracket See figure 5 2 Check if the unit is horizontally levelled Do not install the unit tilted The indoor unit is equipped with a built in drain pump and float switch If the unit...

Page 7: ...nside the building If the drain hose cannot be sufficiently set on a slope fit the hose with drain raising piping field supply HOW TO PERFORM PIPING See figure 8 Connect the drain hose to the drain ra...

Page 8: ...ndoor unit are mismatched the system may cause a malfunction Electrical characteristics MCA Min circuit Amps A MFA Max Fuse Amps A KW Fan Motor Rated Output kW FLA Full Load Amps A Specifications for...

Page 9: ...mote controller supplied with the remote controller 6 Never connect the power supply wiring to the terminal board for transmission wiring This mistake could damage the entire system 7 Use only specifi...

Page 10: ...to half the time inbetween 2 filter cleaning display indications Ultra long life filter Light 10 000 hrs Heavy 5 000 hrs Long life filter 2 500 hrs 1 250 hrs Standard filter 200 hrs 100 hrs 2 Thermos...

Page 11: ...installed in a room where the air is extremely contaminated If the dirt becomes impossible to clean change the air filter Air filter for exchange is optional 1 Open the suction grille Only for bottom...

Page 12: ...et are not blocked Remove any obstacle Check if the earth is connected Clean the air filter and outside panels After cleaning the air filter make sure to attach it Turn on the main power supply switch...

Page 13: ...ADAPTOR FOR WIRING RyC RyF MAGNETIC RELAY RyH MAGNETIC RELAY J1EH F1U F2U FUSE 250 V 5 A X1A X2A CONNECTOR WIRING ADAPTOR X1M TERMINAL STRIP CONNECTOR FOR OPTIONAL PARTS X16A CONNECTOR WIRING ADAPTOR...

Page 14: ...NOTES NOTES...

Page 15: ...1 T2 LN P1 P2 P1 P2 F1 F2 T1 T2 LN LN P1 P2 P1 P2 F1 F2 T1 T2 3 4 2 1 13 12 2 2 1 14 16 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P...

Page 16: ...4PW47630 1 Copyright Daikin...

Reviews: