background image

FMDQ50~125A7V3B
Air conditioning system
4PW47630-1

Installation and operation manual

8

I

NSTALLATION

 

OF

 

THE

 

DECORATION

 

PANEL

Refer to the installation manual attached to the decoration panel.

After installing the decoration panel, ensure that there is no space
between the unit body and decoration panel.

T

EST

 

OPERATION

Refer to the installation manual of the outdoor unit.

The operation lamp of the remote controller will flash when an error
occurs. Check the error code on the liquid crystal display to identify
the trouble. An explanation of error codes and the corresponding
trouble is provided on the "Caution for servicing" sticker on the indoor
units switch box.

PRECAUTIONS

In case something is wrong with the unit and it does not operate,
refer to the malfunction diagnosis label attached to the unit.

M

AINTENANCE

How to clean the air filter

Clean the air filter when the display shows "

" (TIME TO CLEAN

AIR FILTER).

Increase the frequency of cleaning if the unit is installed in a room
where the air is extremely contaminated.

If the dirt becomes impossible to clean, change the air filter. (Air filter
for exchange is optional.)

1

Open the suction grille. (Only for bottom suction.)

Slide both knobs simultaneously as shown and then pull them
downward.

If chains are present, unhook the chains.

1

Drain pumping device (built-in) drain water is removed from the 
room during cooling.

2

Air filter (inside suction grill)

3

Air outlet

4

Decoration panel (optional), this is where the room air is drawn 
in.

5

Remote controller

1

2

3

5

4

Caution

Only a qualified service person is allowed to perform
maintenance.

Before obtaining access to terminal devices, all power
supply circuits must be interrupted.

Do not use water or air of 50°C or higher for cleaning
air filters and outside panels.

When cleaning the heat exchanger, be sure to remove
the switchbox, fan motor, auxiliary electric heater and
drain pump. Water or detergent may deteriorate the
insulation of electronic components and result in
burn-out of these components.

If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.

Summary of Contents for FMDQ50A7V3B

Page 1: ...INSTALLATION AND OPERATION MANUAL FMDQ50A7V3B FMDQ60A7V3B FMDQ71A7V3B FMDQ100A7V3B FMDQ125A7V3B Air conditioning system...

Page 2: ...2 5 6 7 4 3 4 4 1 3 2 4 5 5 5 2 1 2 3 6a 6a 2 3 1 4 680 85 6b 6b 1 3 2 4 6 5 50 200 45 680 6c 6c 1 5 2 3 7 4 680 65 3 3 1 4 3 4 2 800 630 B A 145 7c 7c 4 2 2 3 1 460 180 350 A 8 8 1 1 5m 0 625mm 2 6...

Page 3: ...12 gitt i henhold til bestemmelsene i 13 noudattaen m r yksi 14 za dodr en ustanoven p edpisu 15 prema odredbama 16 k veti a z 17 zgodnie z postanowieniami Dyrektyw 18 n urma prevederilor 19 ob upo te...

Page 4: ...volatile flammable gas like thinner or gasoline is used Where machines generating electromagnetic waves exist Control system may malfunction Where the air contains high levels of salt such as air near...

Page 5: ...age interference and noise in those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if 1 meter is kept 2 Use suspension bolts f...

Page 6: ...ides of the hanger bracket See figure 5 2 Check if the unit is horizontally levelled Do not install the unit tilted The indoor unit is equipped with a built in drain pump and float switch If the unit...

Page 7: ...nside the building If the drain hose cannot be sufficiently set on a slope fit the hose with drain raising piping field supply HOW TO PERFORM PIPING See figure 8 Connect the drain hose to the drain ra...

Page 8: ...ndoor unit are mismatched the system may cause a malfunction Electrical characteristics MCA Min circuit Amps A MFA Max Fuse Amps A KW Fan Motor Rated Output kW FLA Full Load Amps A Specifications for...

Page 9: ...mote controller supplied with the remote controller 6 Never connect the power supply wiring to the terminal board for transmission wiring This mistake could damage the entire system 7 Use only specifi...

Page 10: ...to half the time inbetween 2 filter cleaning display indications Ultra long life filter Light 10 000 hrs Heavy 5 000 hrs Long life filter 2 500 hrs 1 250 hrs Standard filter 200 hrs 100 hrs 2 Thermos...

Page 11: ...installed in a room where the air is extremely contaminated If the dirt becomes impossible to clean change the air filter Air filter for exchange is optional 1 Open the suction grille Only for bottom...

Page 12: ...et are not blocked Remove any obstacle Check if the earth is connected Clean the air filter and outside panels After cleaning the air filter make sure to attach it Turn on the main power supply switch...

Page 13: ...ADAPTOR FOR WIRING RyC RyF MAGNETIC RELAY RyH MAGNETIC RELAY J1EH F1U F2U FUSE 250 V 5 A X1A X2A CONNECTOR WIRING ADAPTOR X1M TERMINAL STRIP CONNECTOR FOR OPTIONAL PARTS X16A CONNECTOR WIRING ADAPTOR...

Page 14: ...NOTES NOTES...

Page 15: ...1 T2 LN P1 P2 P1 P2 F1 F2 T1 T2 LN LN P1 P2 P1 P2 F1 F2 T1 T2 3 4 2 1 13 12 2 2 1 14 16 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P...

Page 16: ...4PW47630 1 Copyright Daikin...

Reviews: