9 Relocation

Installation and operation manual

13

FHA-A(9)
Split system air conditioner
3P668115-4E – 2022.11

WARNING

Stop  operation  and  shut  OFF  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause  breakage,  electrical  shock  or  fire.  Contact  your
dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
circuit breaker or a residual current
device frequently actuates or the ON/
OFF switch does NOT function properly.

Turn OFF all main power
supply switches to the
unit.

If water leaks from the unit.

Stop operation.

The operation switch does NOT function
properly.

Turn OFF the power
supply.

If the user interface displays 

.

Notify your installer and
report the error code. To
display an error code see
the reference guide of the
user interface.

If  the  system  does  NOT  operate  properly  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  in  accordance  with  the  following
procedures.

INFORMATION

Refer  to  the  reference  guide  located  on 

https://

www.daikin.eu

  for  more  troubleshooting  tips.  Use  the

search function   to find your model.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

9

Relocation

Contact  your  dealer  to  remove  and  reinstall  the  entire  unit.  Moving
units requires technical expertise.

10

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

For the installer

11

About the box

11.1

Indoor unit

WARNING: MILDLY FLAMMABLE MATERIAL

The  R32  refrigerant  (if  applicable)  in  this  unit  is  mildly
flammable.  Refer  to  the  outdoor  unit  specifications  for  the
type of refrigerant to be used.

11.1.1

To remove the accessories from the
indoor unit

c

a

b

j

l

k

m

n

o

f

g

d

e

h

i

a

General safety precautions

b

Indoor unit installation and operation manual

c

Paper pattern for installation (part of the packing)

d

Drain hose

e

Metal clamp

f

Washer for hanger bracket

g

Tie wraps

h

Insulation piece: Large (gas pipe)

i

Insulation piece: Small (liquid pipe)

j

Large sealing pad

k

Sealing material for gaps around pipes and cables

l

Small sealing pad

m

Resin bushing

n

Wiring fixture

o

Screw for wiring fixture

12

Unit installation

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

12.1

Preparing the installation site

WARNING

The  appliance  using  R32  refrigerant  shall  be  stored  so  as
to  prevent  mechanical  damage  and  in  a  well-ventilated
room  without  continuously  operating  ignition  sources  (e.g.
open  flames,  an  operating  gas  appliance,  or  an  operating
electric heater). The room size shall be as specified in the
General safety precaution.

12.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

Summary of Contents for FHA35AVEB98

Page 1: ...ion and operation manual Split system air conditioner English Installation and operation manual Split system air conditioner FHA35AVEB98 FHA50AVEB98 FHA60AVEB98 FHA71AVEB98 FHA100AVEB8 FHA125AVEB8 FHA...

Page 2: ...ksploatuojami laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi...

Page 3: ...n accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 1091 Electromagnetic Compati...

Page 4: ...el 21 16 Commissioning 21 16 1 Checklist before commissioning 21 16 2 To perform a test run 22 17 Configuration 22 17 1 Field setting 22 18 Technical data 23 18 1 Wiring diagram 23 18 1 1 Unified wiri...

Page 5: ...ersion of ISO14903 can be used CAUTION Install the refrigerant piping or components in a position where they are unlikely to be exposed to any substance which may corrode components containing refrige...

Page 6: ...consequences for the environment and human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NOT b...

Page 7: ...f obstructions Maintenance and service see 7 Maintenance and service 410 CAUTION Pay attention to the fan It is dangerous to inspect the unit while the fan is running Make sure to turn OFF the main sw...

Page 8: ...ant leaks in the room and comes into contact with fire from a burner a heater or a cooker this may result in a fire in case of R32 or the formation of a harmful gas Turn OFF any combustible heating de...

Page 9: ...peration range INFORMATION For the operation limits see the technical data of the connected outdoor unit 6 2 About operation modes INFORMATION Depending on the installed system some operation modes wi...

Page 10: ...become caught or the unit may break down NOTICE Avoid operating in the horizontal direction It may cause dew or dust to settle on the ceiling or flap Left and right airflow direction setting The left...

Page 11: ...ation of the terminals see the warning label for persons performing service and maintenance a a b c a Residual voltage measuring points b Printed circuit board c Control box 7 2 Cleaning the unit exte...

Page 12: ...legislation on fluorinated greenhouse gases requires that the refrigerant charge of the unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes...

Page 13: ...ing units requires technical expertise 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applic...

Page 14: ...n installing optional equipment also read the installation manual of the optional equipment Depending on the field conditions it might be easier to install the optional equipment first Ceiling strengt...

Page 15: ...e accessories b c a a Accessories b Fixing screw for side covers c Decoration side cover To mount the indoor unit 1 Open the knockout hole at the wiring inlet at the rear or the top of the unit and in...

Page 16: ...a T joint To connect the drain piping to the indoor unit NOTICE Incorrect connection of the drain hose might cause leaks and damage the installation space and surroundings Drain piping can be connecte...

Page 17: ...level in accordance with the instructions in 12 2 1 Guidelines when installing the indoor unit 414 Gradually pour approximately 1 l of water through the air discharge outlet and check for leaks a 100...

Page 18: ...DLY FLAMMABLE MATERIAL The R32 refrigerant if applicable in this unit is mildly flammable Refer to the outdoor unit specifications for the type of refrigerant to be used Refrigerant piping can be conn...

Page 19: ...y III WARNING If the supply cord is damaged it MUST be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 14 1 Specifications of standard wiring c...

Page 20: ...tion of power supply cable m Wiring fixture fixed with a screw accessory n Tie wrap accessory 6 Seal all gaps with sealing material accessory to prevent small animals from entering the system 7 Reatta...

Page 21: ...To open the indoor unit 415 2 When installing the suction grille attach the strap of the suction grille to the hook on the indoor unit INFORMATION When closing the suction grille make sure the straps...

Page 22: ...When using any other user interface see the installation manual or service manual of the user interface Setting Wireless remote controller address if applicable When using wireless remote controller s...

Page 23: ...er interface to master unit The system does not operate properly when two or more user interfaces are attached in the simultaneous operation system mode Setting T1 T2 input setting Remote control is a...

Page 24: ...essor motor M F Fan motor M P Drain pump motor M S Swing motor MR MRCW MRM MRN Magnetic relay N Neutral n N Number of passes through ferrite core PAM Pulse amplitude modulation PCB Printed circuit boa...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...3P668115 4E 2022 11 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: