background image

 

„

CHARACTERISTICS OF THE HEATING 

OPERATION (HEATING OPERATION AND 

AUTOMATIC HEATING OPERATION)

START OF OPERATION

• 

It generally takes a longer time for indoor 

temperature of the HEATING OPERATION 

to reach the set temperature compared to 

the COOLING OPERATION. It is advisable to 

start operation in advance using the TIMER 

OPERATION.

After operation is stopped

• 

The fan operates for about 1 minute to dispel 

heat inside the indoor unit.

Perform the following operation to prevent 

heating capacity decrease and discharge of 

cool air.

AT THE START OF OPERATION AND 

AFTER DEFROST OPERATION

• 

A warm air circulating system is employed, 

and therefore it takes some time until the entire 

room is warmed up after the start of operation.

• 

The indoor fan runs to discharge a gentle wind 

automatically until the temperature inside the 

air conditioner reaches a certain level. At this 

time, the DEFROST OPERATION LAMP on the 

light receiving unit indicator lights. Leave it as it 

stands and wait for a while.  

(The remote controller displays the fan speed 

that is set.)

• The air discharge direction becomes horizontal 

to prevent a draft of cool air to the inhabitants. 

(The remote controller will display the set 

airflow direction.)

DEFROST OPERATION (Frost removal 

operation for the outdoor unit)

• 

As the frost on the coil of an outdoor unit 

increase, heating effect decreases and the 

system goes into the DEFROST OPERATION.

• 

The warm air stops, and the DEFROST 

OPERATION LAMP on the light receiving unit 

turn on. (The remote controller displays the fan 

speed that is set.)

• 

After maximum 10 minutes of the DEFROST 

OPERATION, the air conditioner returns to the 

HEATING OPERATION.

• The airflow direction becomes horizontal. (The 

remote controller displays the airflow direction 

that is set.)

• 

During or after the DEFROST OPERATION, 

white mist comes out from the air inlet or outlet 

of the air conditioner.

• 

A hissing and “Shuh” sound may be heard 

during this particular operation.

Regarding outside air temperature and 

heating capacity

• 

The heating capacity of the air conditioner 

declines as the outside air temperature falls. 

In such a case, use the air conditioner in 

combination with other heating systems. 

(When a combustion appliance is used, 

ventilate the room regularly.) 

Do not use the combustion appliance where 

the air from the air conditioner is blown directly 

toward it.

• 

When the warm air stays under the ceiling and 

your feet are cold, we recommend that you use 

a circulator (a fan to circulate the air inside the 

room). For details, consult your local dealer.

• 

When the indoor temperature exceeds the 

set temperature, the indoor unit discharges a 

gentle breeze (switches to gentle wind). The 

airflow direction becomes horizontal. (The 

remote controller displays the fan speed and 

airflow direction that are set.)

FAN OPERATION

• 

Only the fan inside the indoor unit operates, 

and the air in the room is circulated.

 

„

CHARACTERISTICS OF THE DRY 

OPERATION

• 

This operation lowers the humidity without 

lowering the indoor temperature. The indoor 

temperature when the operation button is 

pressed will be the set temperature. At this 

time, the fan speed and temperature are set 

automatically, so the remote controller does not 

display the fan speed and set temperature. 

To efficiently lower the indoor temperature and 

humidity, first use the COOLING OPERATION 

to lower the indoor temperature, and then 

use the DRY OPERATION. When the indoor 

temperature is lowered, airflow from the indoor 

unit may stop.

• 

When operating continuously at downward 

airflow direction, air blows in the automatically 

set direction for a period of time to prevent 

condensation on the horizontal blades.

• 

If the DRY OPERATION is used when the 

indoor temperature is low, frost forms on the 

heat exchanger of the indoor unit. In this case, 

the system automatically switches to the 

DEFROST OPERATION for a while.

English

02_EN_3P477582-1.indd   7

6/15/2017   15:17:40

Summary of Contents for FFA25RV1A

Page 1: ...ar round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FFA25RV1A FFA35RV1A FFA50RV1A F...

Page 2: ...roperly may result in personal injury or loss of life Failure to follow these instructions properly may result in property damage or personal injury which may be serious depending on the circumstances...

Page 3: ...damage to the unit and personal injury To avoid electric shock do not operate with wet hands Do not start or stop operating the air conditioner with the power supply circuit breaker turned ON or OFF...

Page 4: ...insert the batteries in the wrong polarity orientation as this may result in short circuiting fire or battery leakage Do not remove the outdoor unit s fan guard The guard protects against the unit s...

Page 5: ...arance of the remote controller may differ between different models Wired type Wireless type Decoration panel Remote controller For details on remote controller operation refer to the operation manual...

Page 6: ...ting active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programming during installation Please consult your ret...

Page 7: ...ation mode in room B C and D Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN The current operation mode is maintained HEAT The unit enters the standby mode Ope...

Page 8: ...e tasks to prevent it from falling out Quick reference Cleaning parts NOTE For cleaning do not use any of the following Water hotter than 40 C Volatile liquid such as benzine petrol and thinner Polish...

Page 9: ...er downward to disconnect the hooks and remove the air filter Hook Knob 3 Clean the air filter with a vacuum cleaner or wash it with water If the dust does not come off easily Wash the air filter usin...

Page 10: ...e suction grille Refer to STEP 2 7 Close the suction grille Refer to STEP 1 Prior to a long period of non use 1 Operate the FAN mode for several hours to dry out the inside To start the operation refe...

Page 11: ...r conditioner The outdoor fan rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 30 seconds for system protection While the...

Page 12: ...lems electric shock or fire Consult the dealer where you bought the air conditioner Do not attempt to repair or modify the air conditioner by yourself Incorrect work may result in electric shock or fi...

Page 13: ...12 Memo...

Page 14: ...13 Memo...

Page 15: ...14...

Page 16: ...3P472684 7 M16B254 1708 HT The two dimensional bar code is a manufacturing code...

Page 17: ...WIRELESS REMOTE CONTROLLER KIT OPERATION MANUAL MODELS BRC086A21 BRC086A22...

Page 18: ...ig 1 1 13 2 6 1 3 7 8 12 10 9 11 4 5 Fig 1 2 18 14 19 17 20 15 16 Fig 2 CEILING MOUNTED CASSETTE TYPE 2x2 Sold separately SIGNAL RECEIVER UNIT SEPARATE TYPE Sold separately Receiver 21 25 22 23 24 26...

Page 19: ...ories are attached to this kit Name 1 Wireless remote controller 2 Remote controller holder 3 Dry cell battery AAA LR03 alkaline Quantity 1 1 2 Shape Name 4 Operation manual 5 Remote controller holder...

Page 20: ...ction After reading keep this manual in a convenient place so that you can refer to it whenever necessary If the equipment is transferred to a new user be sure also to hand over the manual WARNING Do...

Page 21: ...it stand and its mounts for damage If they are left in a damaged condition the unit may fall and cause injury To avoid injury do not touch the air inlet or aluminium fins of the indoor or outdoor unit...

Page 22: ...PERATURE SETTING BUTTON Use this button for SETTING TEMPERATURE 12 BACKLIGHT BUTTON Press this button to turn the backlight on or off 13 SIGNALTRANSMITTER This sends the signals to the indoor unit 14...

Page 23: ...ELESS REMOTE CONTROLLER Precautions in handling remote controller Direct the transmitting part of the remote controller to the receiving part of the air conditioner If something blocks the transmittin...

Page 24: ...e screws supplied with the holder 3 Place the remote controller in the remote controller holder NOTE Notes on batteries To avoid possible injury or damage from battery leakage or rupturing remove the...

Page 25: ...air temperature when starting operation by DRY operation Micro computer automatically determines TEMPERATURE and FAN SPEED DRY operation will not activate when room temperature is 16 C or less 2 ON O...

Page 26: ...om the air inlet or outlet of the air conditioner A hissing and Shuh sound may be heard during this particular operation Regarding outside air temperature and heating capacity The heating capacity of...

Page 27: ...connected In Auto the fan speed is adjusted according to the set temperature and the temperature in the room However in FAN OPERATION mode fan speed is fixed The fan speed will not be displayed if th...

Page 28: ...is effective only once When using the TIMER operation every day the setting is required before each use Setting the timer 1 TIMER MODE ON OFF Press theTIMER MODE ON OFF button The display flashes For...

Page 29: ...ems beside individual control 1 remote controller controls 1 indoor unit system Confirm the following if your system is of the following control system type 2 remote controller control system 2 remote...

Page 30: ...long beeping sound An unavailable mode was set for the indoor unit under operation changeover control III THERE IS NO DISPLAY OR ALL PARTS ARE DISPLAYED When a button on the remote controller is pres...

Page 31: ...t beeps Perform all steps from 3 to 6 1 short beep Perform 3 and 6 steps 1 long beep Normal state 3 Press OPERATION MODE SELECTOR button on the left hand of the malfunction code blinks 4 Press PROGRAM...