Removal of Drain Pump Cover
Si07-863
14
Removal Procedure
6. Removal of Drain Pump Cover
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the drain pump
Remark:
It is not necessary to remove
the PCB before you remove
the drain pump.
1
Remove the one screw
from the drain pump
cover.
2
Move the drain pump
cover to the left and
remove it.
3
You can check the float