background image

Table of Contents

Installation manual

4

FDXM25~60F3V1B(9)

Split system air conditioners

4P472267-1B – 2018.07

Table of Contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 About the box

4

2.1

Indoor unit .................................................................................

4

2.1.1

To remove the accessories from the indoor unit.........

4

3 About the units and options

5

3.1

System layout ............................................................................

5

4 Preparation

5

4.1

Preparing the installation site ....................................................

5

4.1.1

Installation site requirements of the indoor unit ..........

5

5 Installation

5

5.1

Mounting the indoor unit............................................................

5

5.1.1

Guidelines when installing the indoor unit...................

5

5.1.2

Guidelines when installing the ducting........................

6

5.1.3

Guidelines when installing the drain piping.................

7

5.2

Connecting the refrigerant piping ..............................................

8

5.2.1

To connect the refrigerant piping to the indoor unit ....

8

5.2.2

To check for leaks.......................................................

8

5.3

Connecting the electrical wiring.................................................

8

5.3.1

To connect the electrical wiring on the indoor unit......

8

5.3.2

Specifications of standard wiring components............

9

6 Commissioning

9

6.1

Checklist before commissioning ................................................

9

6.2

To perform a test run .................................................................

9

6.3

Error codes when performing a test run ....................................

10

7 Disposal

10

8 Technical data

10

8.1

Wiring diagram ..........................................................................

11

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Indoor unit

WARNING: FLAMMABLE MATERIAL

The  R32  refrigerant  (if  applicable)  in  this  unit  is  mildly
flammable.  Refer  to  the  outdoor  unit  specifications  for  the
type of refrigerant to be used.

2.1.1

To remove the accessories from the
indoor unit

24×

e

d

b

a

c

f

g

h

i

j

k

l

m

n

a

Installation manual

b

Operation manual

c

General safety precautions

d

Washers for hanger bracket

e

Screws for duct flanges

f

Metal clamp

g

Sealing pads: small and large

h

Drain hose

i

Sealing material

j

Insulation piece: Small (liquid pipe)

k

Insulation piece: Large (gas pipe)

l

Tie wraps

m

Washer fixing plate

n

Air filter

Summary of Contents for FDXM25F3V1B9

Page 1: ...allation manual Split system air conditioners English Installation manual Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B FDXM25F3V1B9 FDXM35F3V1B9 FDXM50F3V1B9 FDXM60F3V...

Page 2: ...ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis...

Page 3: ...acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis t...

Page 4: ...s or for commercial and household use by lay persons Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you...

Page 5: ...d a mm 400 A Minimum distance to the floor 2 7 m to avoid accidental touching 2 5 m in case the fan is covered e g false ceiling grille a Control box b Maintenance space c Ceiling d Floor surface e Se...

Page 6: ...rear suction bottom suction 2 1 2 1 Install the unit temporarily 6 Attach the hanger bracket to the suspension bolt 7 Fix the unit securely Level Make sure the unit is level at all four corners using...

Page 7: ...00 to prevent air from being trapped in the piping Use hanging bars as shown 1 1 5 m a a Hanging bar O Allowed X Not allowed Condensation Take measures against condensation Insulate the complete drain...

Page 8: ...recommended bubble test solution from your wholesaler Do not use soap water which may cause cracking of flare nuts soap water may contain salt which absorbs moisture that will freeze when the piping g...

Page 9: ...e properly mounted In case a wireless user interface is used The indoor unit decoration panel with infrared receiver is installed The outdoor unit is properly mounted There are NO missing phases or re...

Page 10: ...ly set temperature is not displayed The wiring is disconnected or there is a wiring error between power supply and outdoor unit between outdoor unit and indoor units between indoor unit and user inter...

Page 11: ...LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIGHT EMITTING DIODE SERVICE MONITOR GREEN HIGH VOLTAGE HIGH VOLTAGE IES INTELLIGENT EYE SENSOR IPM INTELLIGENT POWER MODULE K R KCR KFR KHuR K M MAGNETIC...

Page 12: ...4P472267 1B 2018 07 Copyright 2017 Daikin...