background image

Care and Cleaning

 CAUTION

•  Only a qualifi ed service person is allowed to perform maintenance.
• 

Before cleaning, be sure to stop the operation and turn off the circuit breaker.

•  Do not touch the aluminium fi ns of the indoor unit. If you touch those parts, this may cause an injury.

„

 How to clean the air fi lter

When the remote controller indicates “Time to clean filter”, clean the air filter.

• 

It indicates after running for a certain time.

NOTE

For cleaning, do not use any of the following:

• 

Volatile liquid such as benzene, gasoline and thinner

• 

Polishing compounds

• 

Rough materials such as a scrubbing brush

• You may change the time of indication “Time to clean filter”.

If the indoor unit is used in a space where the air is too contaminated, ask your local dealer for solution�

Contamination

Time until indication is displayed

Normal

2500 hours
(equivalent to one year)

More contaminated

1250 hours
(equivalent to a half year)

• If it becomes diffi cult to remove contamination from the air fi lter, replace the air fi lter. 

(Air fi lter for replacement is a separately sold accessory.)

• Do not remove the air fi lter except when cleaning. Unnecessary handling may damage the fi lter. 

(This product is not provided with an air fi lter as a standard accessory.)

• Do not attach objects other than the genuine air fi lter (e.g., kitchen paper) to the air inlet.

Otherwise, the performance of the air conditioner will be degraded, and icing or water leakage may result.

• 

This product is a ceiling mounted duct type air conditioner.

Installing under roof

If the air filter (sold separately) is used, request a special contractor for the cleaning of the air filter.

Not installing under roof

Always use the long-life filter chamber (sold separately). Be sure to request your dealer for the installation of the long-life chamber. For the methods 
of mounting, dismounting, and cleaning the air filter, refer to the manual provided with the air filter.

• Be sure to use the separately sold fi lter chamber.

Request your dealer for the installation of the filter chamber.

• Be sure to clean the air fi lter at the beginning of the cooling or heating season. 

(A decrease in the airfl ow volume of the air conditioner will result and the performance of the air conditioner will be degraded if the air fi lter is clogged 

with dust or dirt.)

Increase the frequency of cleaning if the unit is installed in a room where the air is extremely contaminated.

After completing cleaning and installing an air filter, turn off the indication of “Time to clean filter” on the remote controller�

• 

Press the FILTER SIGN RESET button.

• 

The indication can be turned off while the unit is either operating or stopped.

       English

01_EN_3P500431-1.indd   7

10/12/2017   11:57:50

Summary of Contents for FDMQ12RVJU

Page 1: ...oy year round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL English Fran ais Espa ol MODELS FDMQ09RVJU FDMQ12RVJU FDMQ...

Page 2: ...in equipment or property damage accidents only DANGER Do not install the unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death Any abnorm...

Page 3: ...t from lightning or other sources may cause damage to the air conditioner Be sure to install a ground fault circuit interrupter Failure to install a ground fault circuit interrupter may result in elec...

Page 4: ...ith a mist of mineral oil such as cutting oil b Locations such as coastal areas where there is a lot of salt in the air c Locations such as hot springs where there is a lot of sulfur in the air d Loca...

Page 5: ...r temperature sensor back Model name Indoor Unit a b c d e f g h i j k l m a Drain discharge device built in g Refrigerant piping b Drain pan inspection window h Drain piping c Remote controller Wired...

Page 6: ...ng active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programing during installation Please consult your retail...

Page 7: ...erent operation mode from other rooms Example Room A is the priority room in this example When COOL operation is selected in room A while operating the following modes in room B C and D Operation mode...

Page 8: ...d accessory Do not attach objects other than the genuine air filter e g kitchen paper to the air inlet Otherwise the performance of the air conditioner will be degraded and icing or water leakage may...

Page 9: ...select FAN operation When a multi outdoor unit is connected make sure the HEAT operation is not being used in other rooms before you use the FAN operation Page 5 2 Press the ON OFF button and start o...

Page 10: ...an rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 1 minute for system protection While the air conditioner is not in op...

Page 11: ...may result in problems electric shock or fire Consult the dealer where you bought the air conditioner Do not attempt to repair or modify the air conditioner by yourself Incorrect work may result in e...

Page 12: ...The two dimensional bar code is a manufacturing code 3P500431 1 M17B178 1711 HT...

Reviews: