background image

Contents

Safety Considerations

 

„

Read Before Operation

Safety Considerations  ................................. 

1

Names of Parts  ........................................... 

4

 

„

Multi Connection

Note for Multi System  ................................. 

5

 

„

Care

Care and Cleaning  ...................................... 

7

 

„

When the Need Arises

Troubleshooting  .......................................... 

9

Read these 

Safety Considerations for Operations

 carefully 

before operating an air conditioner or heat pump. 
Make sure that the unit operates properly during the startup 
operation. Instruct the user on how to operate and maintain 
the unit.  
Inform users that they should store this operation manual with 
the installation manual for future reference. 
Meanings of 

DANGER

WARNING

CAUTION

, and 

NOTE

 

Symbols:

 DANGER  �����������

Indicates an imminently hazardous 
situation which, if not avoided, will 
result in death or serious injury.

 WARNING  ���������

Indicates a potentially hazardous 
situation which, if not avoided, 
could result in death or serious 
injury.

 CAUTION  ����������

Indicates a potentially hazardous 
situation which, if not avoided, may 
result in minor or moderate injury.  
It may also be used to alert against
unsafe practices.

 NOTE  ����������������

Indicates situations that may result 
in equipment or property-damage 
accidents only.

  

 DANGER 

•  Do not install the unit in an area where flammable 

materials are present due to risk of explosion resulting in 
serious injury or death.

• 

Any abnormalities in the operation of the air conditioner or 

heat pump, such as smoke or fire, could result in severe 

injury or death. Turn off the power and contact your dealer 
immediately.

• 

Refrigerant gas may produce toxic gas if it comes into 

contact with fire, such as from a fan heater, stove, or 

cooking device. Exposure to this gas could cause severe 
injury or death.

• 

For refrigerant leakage, consult your dealer.  
Refrigerant gas is heavier than air and replaces oxygen. 
A massive leak could lead to oxygen depletion, especially 
in basements, and an asphyxiation hazard could occur 
leading to serious injury or death.

• 

If equipment utilizing a burner is used in the same room 
as the air conditioner or heat pump, there is the danger 

of oxygen deficiency which could lead to an asphyxiation 

hazard resulting in serious injury or death. Be sure to 

ventilate the room sufficiently to avoid this hazard.

• 

Safely dispose of the packing materials. Packing 
materials, such as nails and other metal or wooden parts, 
may cause stabs or other injuries.

       English

01_EN_3P500431-1.indd   1

10/12/2017   11:57:49

Summary of Contents for FDMQ12RVJU

Page 1: ...oy year round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL English Fran ais Espa ol MODELS FDMQ09RVJU FDMQ12RVJU FDMQ...

Page 2: ...in equipment or property damage accidents only DANGER Do not install the unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death Any abnorm...

Page 3: ...t from lightning or other sources may cause damage to the air conditioner Be sure to install a ground fault circuit interrupter Failure to install a ground fault circuit interrupter may result in elec...

Page 4: ...ith a mist of mineral oil such as cutting oil b Locations such as coastal areas where there is a lot of salt in the air c Locations such as hot springs where there is a lot of sulfur in the air d Loca...

Page 5: ...r temperature sensor back Model name Indoor Unit a b c d e f g h i j k l m a Drain discharge device built in g Refrigerant piping b Drain pan inspection window h Drain piping c Remote controller Wired...

Page 6: ...ng active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programing during installation Please consult your retail...

Page 7: ...erent operation mode from other rooms Example Room A is the priority room in this example When COOL operation is selected in room A while operating the following modes in room B C and D Operation mode...

Page 8: ...d accessory Do not attach objects other than the genuine air filter e g kitchen paper to the air inlet Otherwise the performance of the air conditioner will be degraded and icing or water leakage may...

Page 9: ...select FAN operation When a multi outdoor unit is connected make sure the HEAT operation is not being used in other rooms before you use the FAN operation Page 5 2 Press the ON OFF button and start o...

Page 10: ...an rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 1 minute for system protection While the air conditioner is not in op...

Page 11: ...may result in problems electric shock or fire Consult the dealer where you bought the air conditioner Do not attempt to repair or modify the air conditioner by yourself Incorrect work may result in e...

Page 12: ...The two dimensional bar code is a manufacturing code 3P500431 1 M17B178 1711 HT...