background image

Table of Contents

Installation and operation manual

3

FCAHG71~140HVEB
Split system air conditioners
4P535639-1B – 2019.01

Table of Contents

1 About the documentation

3

1.1

About this document..................................................................

3

For the installer

4

2 About the box

4

2.1

Indoor unit .................................................................................

4

2.1.1

To remove the accessories from the indoor unit.........

4

3 Preparation

4

3.1

Preparing the installation site ....................................................

4

3.1.1

Installation site requirements of the indoor unit ..........

4

4 Installation

5

4.1

Mounting the indoor unit............................................................

5

4.1.1

Guidelines when installing the indoor unit...................

5

4.1.2

Guidelines when installing the drain piping.................

6

4.2

Connecting the refrigerant piping ..............................................

7

4.2.1

To connect the refrigerant piping to the indoor unit ....

7

4.3

Connecting the electrical wiring.................................................

7

4.3.1

Specifications of standard wiring components............

8

4.3.2

To connect the electrical wiring on the indoor unit......

8

5 Configuration

8

5.1

Field settings .............................................................................

8

6 Commissioning

10

6.1

Checklist before commissioning ................................................

10

6.2

To perform a test run .................................................................

10

6.3

Error codes when performing a test run ....................................

11

7 Disposal

11

8 Technical data

11

8.1

Piping diagram: Indoor unit .......................................................

11

8.2

Wiring diagram ..........................................................................

11

8.2.1

Unified wiring diagram legend..................................... 11

For the user

12

9 About the system

12

10 User interface

13

11 Before operation

13

12 Operation

13

12.1

Operation range ........................................................................

13

12.2

Operating the system ................................................................

13

12.2.1

About operating the system ........................................ 13

12.2.2

About cooling, heating, fan only, and automatic
operation ..................................................................... 13

12.2.3

About the heating operation........................................ 13

12.2.4

To operate the system ................................................ 14

12.3

Using the dry program ...............................................................

14

12.3.1

About the dry program ................................................ 14

12.3.2

To use the dry program............................................... 14

12.4

Adjusting the air flow direction...................................................

14

12.4.1

About the air flow flap .................................................. 14

12.5

Active circulation airflow ............................................................. 14

12.5.1

To start the active circulation airflow............................ 14

13 Maintenance and service

15

13.1

Precautions for maintenance and service .................................. 15

13.2

Cleaning the air filter, suction grille, air outlet and outside
panels ......................................................................................... 15

13.2.1

To clean the air filter .................................................... 15

13.2.2

To clean the suction grille ............................................ 16

13.2.3

To clean the air outlet and outside panels ................... 16

13.3

Maintenance after a long stop period ......................................... 16

13.4

Maintenance before a long stop period ...................................... 16

13.5

About the refrigerant................................................................... 16

14 Troubleshooting

17

15 Disposal

17

1

About the documentation

1.1

About this document

Target audience

Authorised inst end users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation and operation manual:

▪ Installation and operation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer and user reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

Summary of Contents for FCAHG71HVEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAHG71HVEB FCAHG100HVEB FCAHG125HVEB FCAHG140HVEB...

Page 2: ...abljajo v skladu z na imi navodili on vastavuses j rgmis t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus...

Page 3: ...culation airflow 14 12 5 1 To start the active circulation airflow 14 13 Maintenance and service 15 13 1 Precautions for maintenance and service 15 13 2 Cleaning the air filter suction grille air outl...

Page 4: ...n 70 dBA CAUTION Appliance not accessible to the general public install it in a secured area protected from easy access This unit both indoor and outdoor is suitable for installation in a commercial a...

Page 5: ...4 a1 Nut field supply a2 Double nut field supply b Washer accessories c Hanger bracket attached to the unit Paper pattern for installation upper part of the packing Use the paper pattern to determine...

Page 6: ...accessory b Drain hose accessory c Rising drain piping vinyl pipe of 25 mm nominal diameter and 32 mm outer diameter field supply d Hanging bars field supply Condensation Take measures against condens...

Page 7: ...are constructed of materials that are inherently resistant to corrosion or are suitably protected against corrosion WARNING FLAMMABLE MATERIAL The R32 refrigerant if applicable in this unit is mildly...

Page 8: ...h the numbers on the outdoor unit and connect the earth wire and fix the cable with a cable tie 4 Divide the small sealing accessory and wrap it around the cables to prevent water from entering the un...

Page 9: ...ification is displayed on the user interface When using a wireless user interface you must also set the address see the installation manual of the user interface If you want an interval of air contami...

Page 10: ...amaged components or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks The correct pipe size is installed and the pipes are properly insulated The stop valves...

Page 11: ...cked E7 There is a missing phase in case of three phase power supply units Note Operation will be impossible Turn OFF the power recheck the wiring and switch two of the three electrical wires L4 The a...

Page 12: ...N Neutral n N Number of passes through ferrite core PAM Pulse amplitude modulation PCB Printed circuit board PM Power module PS Switching power supply PTC Thermistor PTC Q Insulated gate bipolar trans...

Page 13: ...12 Operation 12 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation In combination with R410A outdoor units Outdoor units Cooling Heating...

Page 14: ...flow units For the following conditions a micro computer controls the air flow direction which may be different from the display Cooling Heating When the room temperature is lower than the set tempera...

Page 15: ...f If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth CAUTION Before accessing terminal devices make sure to...

Page 16: ...sible consequence Discoloration and deformation Do NOT scrub firmly when washing the blade with water Possible consequence The surface sealing peels off Clean with a soft cloth If it is difficult to r...

Page 17: ...hich the refrigerant leaked has been repaired 14 Troubleshooting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation and shut off th...

Page 18: ......

Page 19: ......

Page 20: ...4P535639 1B 2019 01 Copyright 2018 Daikin...

Reviews: