2 About the box

Installation and operation manual

4

FCAG35~140BVEB

Split system air conditioners

4P535626-1C – 2019.09

For the installer

2

About the box

2.1

Indoor unit

WARNING: FLAMMABLE MATERIAL

The  R32  refrigerant  (if  applicable)  in  this  unit  is  mildly
flammable.  Refer  to  the  outdoor  unit  specifications  for  the
type of refrigerant to be used.

2.1.1

To remove the accessories from the
indoor unit

a

e

f

d

c

b

h

i

m

g

j

k

l

a

Paper pattern for installation (upper part of packing)

b

General safety precautions

c

Indoor unit installation and operation manual

d

Installation guide

e

Washers for hanger brackets

f

Screws (to temporarily attach the paper pattern for
installation to the indoor unit)

g

Cable ties

h

Metal clamp

i

Sealing pads: Large (drain pipe), medium 1 (gas pipe),
medium 2 (liquid pipe), small (electrical wiring)

j

Drain hose

k

Insulation piece: Small (liquid pipe)

l

Insulation piece: Large (gas pipe)

m

Insulation piece (drain pipe)

3

Preparation

3.1

Preparing the installation site

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

3.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

CAUTION

Appliance not accessible to the general public, install it in a
secured area, protected from easy access.

This  unit,  both  indoor  and  outdoor,  is  suitable  for
installation 

in 

commercial 

and 

light 

industrial

environment.

Spacing

. Mind the following requirements:

(mm)

≥1500

≥2000

≥4000

≥1500

A

B

C

b

a

d

a

c

A

Minimum distance to the wall (see below)

B

Minimum and maximum distance to the floor (see below)

C

35~71 class:
≥214 mm:

 In case of installation with standard panel

≥256 mm:

 In case of installation with design panel

≥294 mm:

 In case of installation with self-cleaning panel

≥263 mm:

 In case of installation with fresh air intake kit

100~140 class:
≥256mm: 

In case of installation with standard panel

≥298mm: 

In case of installation with design panel

≥306mm: 

In case of installation with fresh air intake kit

≥316mm: 

In case of installation with self-cleaning panel

a

Indoor unit

b

Lighting (the figure shows ceiling-mounted lighting, but
recessed lighting is also allowed)

c

Air fan

d

Static volume (example: table)

A:  Minimum  distance  to  the  wall

.  Depends  on  the  air  flow

directions towards the wall.

≥1500

≥500

≥200

a

A

A

A

b

c

a

Air outlet and corners open

b

Air outlet closed, corners open (optional blocking pad kit
required)

c

Air outlet and corners closed (optional blocking pad kit
required)

B: Minimum and maximum distance to the floor

:

▪ Minimum: 2.7 m to avoid accidental touching.

▪ Maximum: Depends on the air flow directions and the capacity

class.  Also  make  sure  the  "Ceiling  height"  field  setting
corresponds  with  the  actual  situation.  See 

"5.1  Field

setting" 

[

4

 8].

If air flow direction…

Then B

FCAG35~71

FCAG100~140

All-round

≤3.5 m

≤4.2 m

4-way

(a)

≤4.0 m

≤4.5 m

3-way

(a)

≤3.5 m

≤4.2 m

(a)

Optional blocking kit required

Summary of Contents for FCAG35BVEB

Page 1: ...tion and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAG35BVEB FCAG50BVEB FCAG60BVEB FCAG71BVEB FCAG100BVEB FCAG125BVEB FCAG...

Page 2: ...ojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmis t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurody...

Page 3: ...tion airflow 14 12 5 1 To start the active circulation airflow 14 13 Maintenance and service 15 13 1 Precautions for maintenance and service 15 13 2 Cleaning the air filter suction grille air outlet a...

Page 4: ...from easy access This unit both indoor and outdoor is suitable for installation in a commercial and light industrial environment Spacing Mind the following requirements mm 1500 2000 4000 1500 A B C b...

Page 5: ...Nut field supply a2 Double nut field supply b Washer accessories c Hanger bracket attached to the unit Paper pattern for installation upper part of the packing Use the paper pattern to determine the...

Page 6: ...mp accessory b Drain hose accessory c Rising drain piping vinyl pipe of 25 mm nominal diameter and 32 mm outer diameter field supply d Hanging bars field supply Condensation Take measures against cond...

Page 7: ...ted of materials that are inherently resistant to corrosion or are suitably protected against corrosion WARNING FLAMMABLE MATERIAL The R32 refrigerant if applicable in this unit is mildly flammable Re...

Page 8: ...h the numbers on the outdoor unit and connect the earth wire and fix the cable with a cable tie 4 Divide the small sealing accessory and wrap it around the cables to prevent water from entering the un...

Page 9: ...e installation manual of the user interface If you want an interval of air contamination Then 1 M C1 C2 2500 h light 10 20 0 01 1250 h heavy 02 No notification 3 02 Individual setting in a simultaneou...

Page 10: ...terface When using any other user interface see the installation manual or service manual of the user interface NOTICE Do not interrupt the test run INFORMATION Backlight To perform an ON OFF action o...

Page 11: ...ical wires Error code Possible cause U4 or UF The inter unit branch wiring is not correct UA The outdoor and indoor unit are incompatible 7 Disposal NOTICE Do NOT try to dismantle the system yourself...

Page 12: ...ixed plate T R Transformer TC TRC Transmitter V R V Varistor V R Diode bridge WRC Wireless remote controller X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing s...

Page 13: ...ty ranges for safe and effective operation In combination with R410A outdoor units Outdoor units Cooling Heating RR71 125 15 46 C DB 12 28 C WB RQ71 125 5 46 C DB 10 15 C WB 12 28 C WB 10 27 C DB RXS3...

Page 14: ...the dry program The function of this program is to decrease the humidity in your room with minimal temperature decrease minimal room cooling The micro computer automatically determines temperature an...

Page 15: ...or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire CAUTION After a long use check the unit stand and fitting for damage If damaged the uni...

Page 16: ...air filter 1 2 3 4 Clean the suction grille Wash with a soft bristle brush and water or neutral detergent If the suction grille is very dirty use a typical kitchen cleaner leave it on for 10 min then...

Page 17: ...em is odourless WARNING R410A is a non combustible refrigerant and R32 is a mildly flammable refrigerant they normally don t leak If the refrigerant leaks in the room and comes into contact with fire...

Page 18: ......

Page 19: ......

Page 20: ...4P535626 1C 2019 09 Copyright 2018 Daikin...

Reviews: