WARNING

Never touch the air outlet or the horizontal blades while the
swing  flap  is  in  operation.  Fingers  may  become  caught  or
the unit may break down.

NOTICE

▪ The  movable  limit  of  the  flap  is  changeable.  Contact

your dealer for details. (only for double-flow, multi-flow,
corner, ceiling-suspended and wall-mounted).

▪ Avoid operating in the horizontal direction 

. It may

cause dew or dust to settle on the ceiling or flap.

12

Maintenance and service

NOTICE

Never  inspect  or  service  the  unit  by  yourself.  Ask  a
qualified service person to perform this work. However, as
end  user,  you  may  clean  the  air  filter,  suction  grille,  air
outlet and outside panels.

WARNING

Never replace a fuse with a fuse of a wrong ampere ratings
or  other  wires  when  a  fuse  blows  out.  Use  of  wire  or
copper wire may cause the unit to break down or cause a
fire.

CAUTION

Do not insert fingers, rods or other objects into the air inlet
or  outlet.  Do  not  remove  the  fan  guard.  When  the  fan  is
rotating at high speed, it will cause injury.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

NOTICE

Do  not  wipe  the  controller  operation  panel  with  benzine,
thinner,  chemical  dust  cloth,  etc.  The  panel  may  get
discoloured  or  the  coating  peeled  off.  If  it  is  heavily  dirty,
soak  a  cloth  in  water-diluted  neutral  detergent,  squeeze  it
well  and  wipe  the  panel  clean.  Wipe  it  with  another  dry
cloth.

CAUTION

Before  accessing  terminal  devices,  make  sure  to  interrupt
all power supply.

NOTICE

When  cleaning  the  heat  exchanger,  make  sure  to  remove
the  switch  box,  fan  motor,  drain  pump  and  float  switch.
Water  or  detergent  might  deteriorate  the  insulation  of
electronic  components  and  result  in  burnout  of  these
components.

12.1

Cleaning the air filter, suction
grille, air outlet and outside panels

12.1.1

To clean the air filter

When to clean the air filter

:

▪ Rule  of  thumb:  Clean  every  6  months.  If  the  air  in  the  room  is

extremely contaminated, increase the cleaning frequency.

▪ Depending  on  the  settings,  the  user  interface  can  display  the

TIME  TO  CLEAN  AIR  FILTER 

notification.  Clean  the  air  filter

when the notification is displayed.

▪ If  the  dirt  becomes  impossible  to  clean,  change  the  air  filter

(= optional equipment).

How to clean the air filter

:

NOTICE

Do  NOT  use  water  of  50°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

1

Open the suction grille.

1

2

Remove the air filter.

1

2

3

3

Clean the air filter. Use a vacuum cleaner or wash with water. If
the air filter is very dirty, use a soft brush and neutral detergent.

4

Dry the air filter in the shadow.

5

Reattach the air filter and close the suction grille.

6

Turn ON the power.

7

Press the 

FILTER SIGN RESET

 button.

Result: 

The 

TIME  TO  CLEAN  AIR  FILTER

  notification

disappears from the user interface.

12.1.2

To clean the suction grille

NOTICE

Do  NOT  use  water  of  50°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

1

Open the suction grille.

1

2

Remove the suction grille.

Summary of Contents for FCAG35AVEB

Page 1: ...tion and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAG35AVEB FCAG50AVEB FCAG60AVEB FCAG71AVEB FCAG100AVEB FCAG125AVEB FCAG...

Page 2: ...v e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vas...

Page 3: ...rranty 17 12 3 1 Warranty period 17 12 3 2 Recommended maintenance and inspection 17 13 Troubleshooting 18 13 1 Symptoms that are NOT system malfunctions 18 13 1 1 Symptom The system does not operate...

Page 4: ...door temperature 15 46 C DB Indoor temperature 18 37 C DB 12 28 C WB RQ71 125 Outdoor temperature 5 46 C DB 9 21 C DB 10 15 C WB Indoor temperature 18 37 C DB 12 28 C WB 10 27 C DB Outdoor units Cooli...

Page 5: ...nel 263 mm In case of installation with fresh air intake kit 100 140 class 256mm In case of installation with standard panel 306mm In case of installation with fresh air intake kit 316mm In case of in...

Page 6: ...ern for installation upper part of the packing d Screws accessories Ceiling opening and unit Make sure the ceiling opening is within the following limits Minimum 860 mm to be able to fit the unit Maxi...

Page 7: ...ing Combining drain pipes You can combine drain pipes Make sure to use drain pipes and T joints with a correct gauge for the operating capacity of the units 100 675 mm a a T joint To connect the drain...

Page 8: ...fications for the type of refrigerant to be used Pipe length Keep refrigerant piping as short as possible Flare connections Connect refrigerant piping to the unit using flare connections Insulation In...

Page 9: ...make sure the numbers match with the numbers on the outdoor unit and connect the earth wire and fix the cable with a cable tie 4 Divide the small sealing accessory and wrap it around the cables to pr...

Page 10: ...10 20 0 01 1250 h heavy 02 No notification 3 02 Individual setting in a simultaneous operation system We recommend using the optional user interface to set the slave unit Perform the following steps...

Page 11: ...ng the BRC1E52 or BRC1E53 user interface When using any other user interface see the installation manual or service manual of the user interface NOTICE Do not interrupt the test run INFORMATION Backli...

Page 12: ...and indoor units between indoor unit and user interface The fuse on the outdoor or indoor unit PCB has blown E3 E4 or L8 The stop valves are closed The air inlet or air outlet is blocked E7 There is a...

Page 13: ...OVERLOADPROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIPSWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FORCHARACTERISTICS REFERTOPCBINSIDEYOURUNIT FUSE S C LIMITSWITCH FG...

Page 14: ...ctions of the system For more information about the user interface see the operation manual of the installed user interface 11 Operation 11 1 Operation range Use the system in the following temperatur...

Page 15: ...isplay Hot start In order to prevent cold air from blowing out of an indoor unit at the start of heating operation the indoor fan is automatically stopped The display of the user interface shows It ma...

Page 16: ...oating peeled off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth CAUTION Before accessing terminal devic...

Page 17: ...ly flammable refrigerant they normally don t leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in a fire in case of R32 or the...

Page 18: ...re NOT system malfunctions The following symptoms are NOT system malfunctions 13 1 1 Symptom The system does not operate The air conditioner does not start immediately after the ON OFF button on the u...

Page 19: ...of operating noise changes This noise is caused by the change of frequency 13 1 10 Symptom Dust comes out of the unit When the unit is used for the first time in a long time This is because dust has...

Page 20: ...4P471224 1 2017 03 Copyright 2017 Daikin...

Reviews: