background image

Thank you for purchasing this product unit.
Carefully read this operation manual to ensure 
proper operation.
After reading the manual, 

file

 it away for future 

reference.
Furthermore, make certain that this operation 
manual is handed to a new user when he/she takes 
over the operation.
As this operation manual is dedicated for the indoor 
unit, refer to also the operation manuals attached to 
the outdoor unit and the remote controller.

CONTENTS

  1. SAFETY PRECAUTIONS ............................. 1
  2. WHAT TO DO BEFORE OPERATION ........... 4
  3. OPERATION RANGE .................................... 5
  4. INSTALLATION SITE..................................... 6
  5. OPERATION PROCEDURE .......................... 6
  6. OPERATION CHARACTERISTICS ............... 6
  7. OPTIMUM OPERATION................................ 8
  8. MAINTENANCE 
 

 (FOR SERVICE PERSONNEL) ..................... 8

  9. NOT MALFUNCTION OF THE AIR  
 

 CONDITIONER ........................................... 10

 10. TROUBLESHOOTING ................................ 12

1.  SAFETY PRECAUTIONS

To gain full advantage of the air conditioner’s
functions and to avoid malfunction due to
mishandling, please read this operation manual
carefully before use.
Read the precautions thoroughly to avoid misuse
of the equipment. 
This product comes under the term “appliances not
accessible to the general public”.    

This appliance is intended to be used by 

expert or trained users in shops, in light 

industry and on farms, or for commercial 

use by lay persons.

This appliance can be used by 

children aged from 8 years and above 

and persons with reduced physical, 

sensory or mental capabilities or lack of 

experience and knowledge if they have 

been given supervision or instruction 

concerning use of the appliance in a 

safe way and understand the hazards 

involved. Children shall not play with 

the appliance. Cleaning and user 

maintenance shall only be done by 

persons described in manual.

The appliance is not intended for use by 

unattended young children or persons who are 

incompetent to operate air conditioners.

It may result in injury or electric shocks.

 

WARNING

 .....  Indicates a potentially 

hazardous situation which, 
if not avoided, could result in 
death or serious injury.

 

CAUTION

  ......  Indicates a potentially 

hazardous situation which, if 
not avoided, may result in minor 
or moderate injury.  
It may also be used to alert 
against unsafe practices.

• 

After reading, keep this manual in a 

convenient place so that you can refer to it 

whenever necessary. If the equipment is 

transferred to a new user, be sure also to 

hand over the manual. 

This appliance is filled with R32.

Read the precautions in this manual 

carefully before operating the unit. 

• 

The precautions described herein are 

classified as WARNING and CAUTION. They 

both contain important information regarding 

safety. 

Be sure to observe all precautions without fail.

• 

There are two kinds of safety precaution and 

tips listed in the following.

Summary of Contents for FBA100BVMA

Page 1: ...MODELS Ceiling mounted Duct type FBA50BVMA FBA60BVMA FBA50BAVMA FBA60BAVMA FBA71BVMA FBA100BVMA FBA125BVMA FBA140BVMA OPERATION MANUAL SPLIT SYSTEM Air Conditioner FBA85BVMA...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a defect results from your own workmanship it may result in water leakage electric shocks or a fire 2 WARNING Do not use means to accelerate the defrosting process or to clean other than those recomme...

Page 4: ...y ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner Do not leave the remote controller wherever there is a risk of wetting If water...

Page 5: ...naked flames in places exposed to the airflow from the air conditioner as this may impair combustion of the burner Do not block air inlets nor outlets Impaired airflow may result in insufficient perf...

Page 6: ...e controllers control systems by yourself but be sure to ask your local dealer Read the operation manual attached to the remote controller you are using When using a wireless remote controller refer t...

Page 7: ...kaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection hoods etc Regarding wiring To do wiring ask your local dealer Never do it by yourse...

Page 8: ...After maximum 10 minutes of the DEFROST OPERATION the air conditioner returns to the HEATING OPERATION During or after the DEFROST OPERATION white mist comes out from the air inlet or outlet of the ai...

Page 9: ...1 m or more away from the indoor unit and remote controller Images may become fuzzy and noise may be generated Turn off the power circuit breaker when it is not in use for a long period When the power...

Page 10: ...volume of the air conditioner will result and the performance of the air conditioner will be degraded if the air lter is clogged with dust or dirt After completing cleaning and installing an air filt...

Page 11: ...is supplied to the air conditioner the indoor fan stops for about 10 minutes during the outdoor unit operation to protect the devices The above operation is performed not only at the time of installa...

Page 12: ...RY OPERATION When the room temperature reaches the set temperature during the HEATING OPERATION the outdoor unit stops and the indoor unit goes into gentle wind It takes some time until the fan speed...

Page 13: ...urs during operation the air conditioner automatically restarts immediately after the power supply recovers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or...

Page 14: ...ures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfunctioning giving off a burning odour etc turn...

Page 15: ......

Page 16: ...3P427030 2R M15N109E The two dimensional bar code is a manufacturing code HT 2110...