background image

• 

If

 

the

 

main

 

power

 

supply

 

is

 

turned

 

off

 

dur

ing 

operation,

 

operation

 

will

 

restart

 automatically 

after

 

the

 

power

 

turns

 

back

 

on

 

again.

Read the operation manual attached to the 

remote controller.

6.

 

OPERATION CHARACTERISTICS

 

CHARACTERISTICS OF THE COOLING 

OPERATION (COOLING OPERATION AND 

AUTOMATIC COOLING OPERATION)

• 

If

 

the

 

COOLING

 

OPERATION

 

is

 

used

 when 

the

 

indoor

 

temperature

 

is

 

low,

 

frost

 

forms

 on 

the

 

heat

 

exchanger

 

of

 

the

 

indoor

 

unit.

 

This

 can 

decrease

 

the

 

cooling

 

capacity.

 

In

 

this

 

case,

 the 

air

 

conditioner

 

automatically

 

switches

 

to

 the 

DEFROST

 

OPERATION

 

for

 

a

 

while.

 

During

 

the

 

DEFROST

 

OPERATION,

 

the

 

low

 

f

an 

speed

 

is

 

used

 

to

 

prevent

 

the

 

discharge

 

of

 melt 

water.

 

(The

 

remote

 

controller

 

displays

 

the

 

f

an 

speed

 

that

 

is

 

set.)

• 

When

 

the

 

outdoor

 

temperature

 

is

 

high,

 

it

 

tak

es 

some

 

time

 

until

 

the

 

indoor

 

temperature

 reaches 

the

 

set

 

temperature.

 

6

System relocation

• 

 Consult your Daikin dealer about remodelling 

and relocation.

4.

 

INSTALLATION

 

SITE

Regarding places for installation

• 

Is the air conditioner installed at a well-ven-

tilated place where there are no obstacles 

around?

• 

Do not use the air conditioner in the following 

places.
a.

 

Filled

 

with

 

much

 

mineral

 

oil

 

such

 

as

 

cutting

 

oil

b.

 

Where

 

there

 

is

 

much

 

salt

 

such

 

as

 

a

 beach 

area

c.

 

Where

 

sulfured

 

gas

 

exists

 

such

 

as

 

a

 

hot-spr

ing 

resort

d.

 

Where

 

there

 

are

 

considerable

 

v

oltage 

fluctuations

 

such

 

as

 

a

 

factory

 

or

 

plant

e.

 

Vehicles

 

and

 

vessels

 

f.

 

Where

 

there

 

is

 

much

 

spray

 

of

 

oil

 

and

 

v

apor 

such

 

as

 

a

 

cookery,

 

etc.

g.

 

Where

 

there

 

are

 

machines

 

gener

ating 

electromagnetic

 

waves

h.

 

Filled

 

with

 

acid

 

and/or

 

alkaline

 

steam

 

or

 

vapor

• 

Is a snow protection measure taken?

For details, consult your local dealer about snow 
protection hoods, etc.

Regarding wiring

• 

 

To do wiring, ask your local dealer. Never do it by 
yourself.

• 

Pay attention to running noises, too

• 

Are the following places selected?
a.

 

A

 

place

 

that

 

can

 

sufficiently

 

withstand

 the 

mass

 

of

 

the

 

air

 

conditioner

 

with

 

less

 

r

unning 

noises

 

and

 

vibrations.

b.

 

A

 

place

 

where

 

the

 

hot

 

wind

 

discharged

 from 

the

 

air

 

outlet

 

of

 

the

 

outdoor

 

unit

 

and

 the 

running

 

noises

 

do

 

not

 

cause

 

a

 

nuisance

 to 

neighbours.

• 

Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?
Such

 

obstacles

 

may

 

result

 

in

 declined 

performance

 

and

 

increased

 

running

 

noises.

• 

If abnormal noises occur in use, stop the 

operation of the air conditioner, consult your 

local dealer.

Regarding drainage of drain piping

• 

Is the drain piping carried out properly to

ensure complete drainage?
If

 

drain

 

piping

 

is

 

not

 

carried

 

out

 

properly,

 

dirt

 and 

debris

 

may

 

be

 

accumulated

 

in

 

the

 

drain

 piping 

and

 

cause

 

water

 

leakage.

 

If

 

it

 

occurs,

 

stop

 

the

 air 

conditioner

 

and

 

consult

 

with

 

your

 

local

 

dealer

 

f

or 

assistance.

5.  OPERATION PROCEDURE

• 

Operating

 

procedure

 

varies

 

with

 

heat

 

pump

 type 

and

 

cooling

 

only

 

type.

 

Contact

 

your

 

local

 

dealer

 to 

confirm

 

your

 

system

 

type.

• 

To

 

protect

 

the

 

air

 

conditioner,

 

turn

 

on

 

the

 main 

power

 

switch

 

6

 

hours

 

before

 

operation.

• 

Do

 

not

 

shut

 

off

 

the

 

power

 

supply

 

during

 seasonal 

use

 

of

 

the

 

air

 

conditioner.

 

This

 

is

 

required

 

in

 

order

 

to

 

activate

 

the

 air 

conditioner

 

smoothly.

All wiring must be performed by a qualified
personnel.

Make sure that a separate power supply cir-
cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fied personnel according to local laws and
regulations.

Summary of Contents for FBA100BVMA

Page 1: ...MODELS Ceiling mounted Duct type FBA50BVMA FBA60BVMA FBA50BAVMA FBA60BAVMA FBA71BVMA FBA100BVMA FBA125BVMA FBA140BVMA OPERATION MANUAL SPLIT SYSTEM Air Conditioner FBA85BVMA...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a defect results from your own workmanship it may result in water leakage electric shocks or a fire 2 WARNING Do not use means to accelerate the defrosting process or to clean other than those recomme...

Page 4: ...y ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner Do not leave the remote controller wherever there is a risk of wetting If water...

Page 5: ...naked flames in places exposed to the airflow from the air conditioner as this may impair combustion of the burner Do not block air inlets nor outlets Impaired airflow may result in insufficient perf...

Page 6: ...e controllers control systems by yourself but be sure to ask your local dealer Read the operation manual attached to the remote controller you are using When using a wireless remote controller refer t...

Page 7: ...kaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection hoods etc Regarding wiring To do wiring ask your local dealer Never do it by yourse...

Page 8: ...After maximum 10 minutes of the DEFROST OPERATION the air conditioner returns to the HEATING OPERATION During or after the DEFROST OPERATION white mist comes out from the air inlet or outlet of the ai...

Page 9: ...1 m or more away from the indoor unit and remote controller Images may become fuzzy and noise may be generated Turn off the power circuit breaker when it is not in use for a long period When the power...

Page 10: ...volume of the air conditioner will result and the performance of the air conditioner will be degraded if the air lter is clogged with dust or dirt After completing cleaning and installing an air filt...

Page 11: ...is supplied to the air conditioner the indoor fan stops for about 10 minutes during the outdoor unit operation to protect the devices The above operation is performed not only at the time of installa...

Page 12: ...RY OPERATION When the room temperature reaches the set temperature during the HEATING OPERATION the outdoor unit stops and the indoor unit goes into gentle wind It takes some time until the fan speed...

Page 13: ...urs during operation the air conditioner automatically restarts immediately after the power supply recovers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or...

Page 14: ...ures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfunctioning giving off a burning odour etc turn...

Page 15: ......

Page 16: ...3P427030 2R M15N109E The two dimensional bar code is a manufacturing code HT 2110...