background image

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/

All rights reserved

c

Warning

z

Daikin products are manufactured for export to numerous countries throughout the world. Prior to 
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this 
product conforms to the applicable standards, and is suitable for use, in the region where the product 
will be used. This statement does not purport to exclude, restrict or modify the application of any local 
legislation.

z

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. 
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

z

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or 
contractor to install those parts and accessories. Use of unauthorised parts and accessories or 
improper installation of parts and accessories can result in water or refrigerant leakage, electrical 
shock, fire or explosion.

z

Read the User's Manual carefully before using this product. The User's Manual provides important 
safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install     

the outdoor unit close to the sea shore, contact your local distributor.

Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING DIVISION

Scope of Registration:
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF 
COMMERCIAL AIR CONDITIONING, HEATING, COOLING, 
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, 
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT 
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT,  
COMPRESSORS AND VALVES.

Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.

Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR 
CONDITIONERS AND THE 
COMPONENTS INCLUDING 
COMPRESSORS USED FOR THEM

All of the Daikin Group’s business 
facilities and subsidiaries in Japan 
are certified under the ISO 14001 
international standard for 
environment management.

JMI-0107

JQA-1452

Dealer

z

Specifications, designs and other content appearing in this brochure are current as of January 2013 but subject to change without notice.

Si281302
01/2013 AK

Summary of Contents for FAQ100BVV1B

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Indoor Unit Inverter Wall Mounted Type 3 4 HP Class Si281302...

Page 2: ...Service Manual Removal Procedure Indoor Unit Applicable Models zHeat Pump FAQ71BVV1B FAQ100BVV1B...

Page 3: ...to Remove Front Grille 3 3 Procedure to Remove the Horizontal Blade and Vertical Blade 4 4 Procedure to Remove Electrical Box 5 5 Procedure to Remove Heat Exchanger 6 6 Procedure to Remove Fan Motor...

Page 4: ...rocedure Points 1 Put your fingers on protrusions at left and right side of the unit to open the front panel 2 To remove the air filter press up the tab and pull down the filter The air filter is free...

Page 5: ...n accordance with Removal of Front Panel 1 Remove 3 pieces of front grille fixing screws 2 Remove the front grille by pulling forward while pushing 3 hooks located at upper part of the grille 1 by 1 I...

Page 6: ...s 1 Removing the horizontal blade 1 Open the horizontal blade 2 Bend the horizontal blade slightly to disengage the fixing part at right side 3 Pull the horizontal blade rightward and take it out 1 Re...

Page 7: ...Grille 1 Remove the screw on the service cover 2 Remove the screw on the drip proof plate 3 Remove the screw for the grounding wire 4 Remove the following connectors Fan motor connector Air swing moto...

Page 8: ...cuum dehydration Caution Don t mix air or the like other than the specified refrigerant into a refrigeration circle Mixing of air or other gas causes abnormal high pressure in the refrigerating cycle...

Page 9: ...Removal of El compo Box 1 Removing the fan motor 1 Insert a Phillips tip screwdriver into the air outlet and remove the screws fixing the fan motor and fan rotor The screws can be removed without rem...

Page 10: ...after turning off all power supplies before disassembling work Step Procedure Points Removing the front grille in accordance with Removal of Front Grille 1 Disconnect the air swing motor connector in...

Page 11: ...e The drain pan and bottom frame are designed as an integral type Insert the drain hose to the hose plug securely as far as it will go 1 Pull out the drain hose attached on the rear right of the unit...

Page 12: ...Revision History Month Year Version Revised contents 01 2013 Si281302 First edition...

Page 13: ...duct The User s Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor an...

Reviews: