Outdoor Unit
SiBE12-713
292
Removal Procedure
1.2
Removal of the Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Disconnect the
connecting wires
Illustrations are for 3 room
model. (4MK(X)S-F models
have 4 ports)
1
Inside structure.
2
Disconnect the
connecting wires.
Connecting wires of the A, B,
C, D port
(1) - Black
Power supply
(2) - White
Power supply
(3) - Red
Transmission
Power Supply wires
(L) - Black
(N) - White
Fasten the wires on the
terminal board with screws.
Summary of Contents for F-Series
Page 1: ... Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump F Series SiBE12 713 ...
Page 11: ...Introduction SiBE12 713 x ...
Page 47: ...Specifications SiBE12 713 36 Specifications ...
Page 113: ...Control Specification SiBE12 713 102 Function and Control ...
Page 122: ...SiBE12 713 Instruction Operation Manual 111 FTK X S 20 25 35 C Names of parts Indoor Unit ...
Page 235: ...Instruction SiBE12 713 224 Operation Manual ...
Page 297: ...Check SiBE12 713 286 Service Diagnosis ...