7
|
Unit installation
Installer reference guide
53
EPRA14~18D + ET23E
Daikin Altherma 3 H HT F
4P644739-1A – 2022.03
7 Unit installation
INFORMATION
This unit is a heating only model. Therefore, all references to cooling in this
document are NOT applicable.
In this chapter
7.1 Preparing the installation site
Choose an installation location with sufficient space to transport the unit in and
out of the site.
Do NOT install the unit in places often used as work place. In case of construction
works (e.g. grinding works) where a lot of dust is created, the unit MUST be
covered.
NOTICE
This unit is designed for operation on 2 temperature zones:
▪
underfloor heating in the
main zone
, this is the zone with the
lowest water
temperature
,
▪
radiators in the
additional zone
, this is the zone with the
highest water
temperature
.
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).