11/12
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[C-04]
R/W
2~10°C, step 1°C
3°C
9.I
[C-05]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-06]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
9.I
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
9.I
[C-09]
R/W
0: Normally open
1: Normally closed
9.I
[C-0A]
0
9.I
[C-0B]
0
9.I
[C-0C]
0
9.I
[C-0D]
0
9.I
[C-0E]
0
9.I
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I
[D-01]
R/W
0: No
1: Active open
2: Active closed
3: Smart Grid
9.I
[D-02]
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.I
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
9.I
[D-04]
R/W
0: No
1: Pwr consmp ctrl
9.I
[D-05]
R/W
0: Forced off
1: As normal
9.I
[D-07]
R/O
0: No
9.I
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.I
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
9.I
[D-0A]
0
9.I
[D-0B]
2
9.I
[D-0C]
0
9.I
[D-0D]
0
9.I
[D-0E]
0
9.I
[E-00]
R/O
0~5
0: LT split
9.I
[E-01]
R/O
1
9.I
[E-02]
R/W (*3)
R/O
0: Reversible (*3)
1: Heating only
9.I
[E-03]
R/O
3: 6V (*1)
4: 9W (*2)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/O
0: No
1: Yes
9.I
[E-06]
1
9.I
[E-07]
R/O
1: Integrated
9.I
[E-08]
R/W
0: disabled
1: Enabled
9.I
[E-09]
1
9.I
[E-0B]
R/O
1: Yes
9.I
[E-0C]
0
9.I
[E-0D]
R/W
0: No
1: Yes
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
20
9.I
[F-02]
3
9.I
[F-03]
5
9.I
[F-04]
0
9.I
[F-05]
0
9.I
[F-09]
R/W
0: Disabled
1: Enabled
--
--
--
--
--
Pump operation during flow abnormality.
--
Is a bi-zone kit installed?
--
Is the system filled with glycol ?
--
Pump operation allowed outside range.
What is the number of backup heater steps?
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
--
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
--
--
Which type of unit is installed?
Which type of compressor is installed?
What is the indoor unit software type?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
--
--
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Contact type of preferential kWh rate PS installation?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
--
--
--
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
(*1) *6V*_(*2) *9W*_
(*3) Only applicable for models where cooling is possible_
(*4) E_(*5) E7
4P644735-1A - 2022.03