10
|
Configuration
Installer reference guide
190
EPRA14~W1 + ETVH/9W
Daikin Altherma 3 H HT F
4P644737-1 – 2021.02
Configuration wizard
After first power ON of the system, the user interface will guide you using the
configuration wizard. This way you can set the most important initial settings. This
way the unit will be able to run properly. Afterwards, more detailed settings can be
done via the menu structure if required.
To restart the configuration wizard, go to
Installer
settings
>
Configuration wizard
[9.1].
Domestic hot water
Domestic hot water
The following setting determines if the system can prepare domestic hot water or
not, and which tank is used. This setting is read only.
#
Code
Description
[9.2.1]
[E‑05]
(a)
[E‑06]
(a)
[E‑07]
(a)
▪
Integrated
The backup heater will also be used for
domestic hot water heating.
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
•
[E-05]: Can the system prepare domestic hot water?
•
[E-06]: Is a domestic hot water tank installed in the system?
•
[E-07]: What kind of domestic hot water tank is installed?
DHW pump
#
Code
Description
[9.2.2]
[D‑02]
DHW pump
:
▪
0:
No DHW pump
: NOT installed
▪
1:
Instant hot water
: Installed for instant
hot water when water is tapped. The user sets
the operation timing of the domestic hot water
pump using the schedule. Control of this pump
is possible with the user interface.
▪
2:
Disinfection
: Installed for disinfection. It
runs when the disinfection function of the
domestic hot water tank is running. No further
settings are needed.
See also:
▪
"6.4.4 DHW pump for instant hot water"
▪
"6.4.5 DHW pump for disinfection"
DHW pump schedule
Program a schedule for the DHW pump
(only for field supplied domestic hot
water pump for secondary return).
Program a domestic hot water pump schedule
to determine when to turn on and
off the pump.
When turned on, the pump runs and makes sure hot water is instantly available at
the tap. To save energy, only turn on the pump during periods of the day when
instant hot water is necessary.