11/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[9-0A]
R/W
[3-07]
~
[3-06]°C, step: 0,5°C
23°C
9.I
[9-0B]
R/W
[3-09]
~
[3-08]°C, step: 0,5°C
23°C
9.I
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
9.I
[9-0D]
R/W
0~8, step:1
0 : No limitation
1~4 : 90~60% pump speed
5~8 : 90~60% pump speed during
sampling
6
9.I
[9-0E]
6
9.I
[C-00]
R/W
0: Solar priority
1: Heat pump priority
9.I
[C-01]
0
9.I
[C-02]
R/W
0: No
1: Bivalent
9.I
[C-03]
R/W
-25~25°C, step: 1°C
0°C
9.I
[C-04]
R/W
2~10°C, step 1°C
3°C
9.I
[C-05]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-06]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
9.I
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
9.I
[C-09]
R/W
0: Normally open
1: Normally closed
9.I
[C-0A]
0
9.I
[C-0B]
0
9.I
[C-0C]
0
9.I
[C-0D]
0
9.I
[C-0E]
0
9.I
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I
[D-01]
R/W
0: No
1: Active open
2: Active closed
3: Smart Grid
9.I
[D-02]
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.I
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
9.I
[D-04]
R/W
0: No
1: Pwr consmp ctrl
9.I
[D-05]
R/W
0: Forced off
1: As normal
9.I
[D-07]
R/W
0: No
1: Yes
9.I
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.I
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
9.I
[D-0A]
0
9.I
[D-0B]
2
9.I
[D-0C]
0
9.I
[D-0D]
0
9.I
[D-0E]
0
9.I
[E-00]
R/O
0~5
0: LT split
9.I
[E-01]
R/O
1
9.I
[E-02]
R/W (*5)
R/O (*6)
0: Reversible (*5)
1: Heating only (*6)
9.I
[E-03]
R/O
3: 6V (*1)
4: 9W (*2)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/W
0: No (*3)
1: Yes (*4)
9.I
[E-06]
1
--
Can the system prepare domestic hot water?
--
--
--
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Contact type of preferential kWh rate PS installation?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
Is the power saving function available on the outdoor unit?
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
--
--
--
--
--
Which type of unit is installed?
What is the thermo request contact type for the main zone?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
What is the indoor unit software type?
What is the number of backup heater steps?
Which type of compressor is installed?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
--
Domestic heating water priority.
--
Is an external backup heat source connected?
Bivalent activation temperature.
What is the unit control method in space operation?
Room temperature hysteresis.
Pump speed limitation
What is the room buffering temperature in heating?
What is the room buffering temperature in Cooling?
Bivalent hysteresis temperature.
What is the thermo request contact type for the add. zone?
(*1) *6V_(*2) *9W_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_(*7) *SU*
(#) Only applicable in Swedish language.
4P644734-1 - 2021.02