12/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[E-07]
R/W
0~8
0: EKHW, small volume (*3)
1: Integrated (*4)
3: EKHW, large volume
5: EKHWP (*3)
7: Third party tank, small coil
8: Third party tank, large coil
9.I
[E-08]
R/W
0: disabled
1: Enabled
9.I
[E-09]
1
9.I
[E-0B]
R/W
0: not installed
1: -
2: Bizone kit installed
9.I
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.I
[E-0D]
R/W
0: No
1: Yes
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
3
9.I
[F-03]
5
9.I
[F-04]
0
9.I
[F-05]
0
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
R/W
0: No
1: Yes
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
Bi-zone kit settings
9.P.1
[E-0B]
R/W
0: not installed
1: -
2: Bizone kit installed
9.P.2
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.P.3
[7-0A]
R/W
20~95%, step 5%
95%
9.P.4
[7-0B]
R/W
20~95%, step 5%
95%
9.P.5
[7-0C]
R/W
20~300 sec, step 5 sec
125 sec
Mixing valve turning time
What is the pump operation mode?
Above which outdoor temperature is cooling allowed?
--
--
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
Is a bi-zone kit installed?
Close shut-off valve during thermo OFF?
Close shut-off valve during cooling?
Bi-zone kit installed
Bi-zone system type
Add zone pump fixed PWM
Main zone pump fixed PWM
--
Pump operation allowed outside range.
--
--
Pump operation during flow abnormality.
--
What bizone system type is installed?
Is the system filled with glycol ?
4P644734-1 - 2021.02
(#) Only applicable in Swedish language.
(*1) *6V_(*2) *9W_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_(*7) *SU*
Summary of Contents for ETVH16S18EA6V