6
|
Application guidelines
Installer reference guide
43
EPRA14~18D + ETSH/X(B)16P30+50E
Daikin Altherma 3 H HT ECH₂O
4P679467-1C – 2023.07
▪
Comfort.
You can set the desired room temperature, including schedules, for
each room via the remote controller of the heat pump convectors.
Combination: Underfloor h Heat pump convectors – Multiple rooms
Setup
B
C
b
M1
a
M1
A
A
Main leaving water temperature zone
B
Room 1
C
Room 2
a
External room thermostat
b
Heat pump convectors (+ controllers)
▪
For more information about connecting the electrical wiring to the unit, see:
-
"9.2 Connections to the outdoor unit"
-
"9.3 Connections to the indoor unit"
▪
For each room with heat pump convectors: The heat pump convectors are
directly connected to the indoor unit.
▪
For each room with underfloor heating: Two shut-off valves (field supply) are
installed before the underfloor heating:
-
A shut-off valve to prevent hot water supply when the room has no heating
demand
-
A shut-off valve to prevent condensation on the floor during cooling operation
of the rooms with heat pump convectors.
▪
For each room with heat pump convectors: The desired room temperature is set
via the controller of the heat pump convectors. There are different controllers
and setups possible for the heat pump convectors. For more information, see:
-
The installation manual of the heat pump convectors
-
The installation manual of the heat pump convector options
-
The addendum book for optional equipment
▪
For each room with underfloor heating: The desired room temperature is set via
the external room thermostat (wired or wireless).
▪
The user interface integrated in the indoor unit decides the space operation
mode. Mind that the operation mode on each external room thermostat and
controller of the heat pump convectors must be set to match the indoor unit.
INFORMATION
To increase comfort and performance, we recommend to install the valve kit option
EKVKHPC on each heat pump convector.
Summary of Contents for ETSXB16E
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ...4P679467 1C 2023 07 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...