10
|
Configuration
Installer reference guide
229
EPRA14~18D + ETSH/X(B)16P30+50E
Daikin Altherma 3 H HT ECH₂O
4P679467-1C – 2023.07
Solar priority
#
Code
Description
[9.O.8]
[C‑00]
▪
0
Yes
: When solar energy is provided and
storage tank temperature is above limit
temperature, heat pump and boiler are
switched off.
▪
1
No
: Heat pump and boiler can operate also
while solar energy is provided.
Bizone kit
Additionally to the settings listed below, make sure to also set [7‑02]=1 (i.e. [4.4]
Number of zones
=
Dual zone
) when a bizone kit is installed.
See also
"6.2.3 Multiple rooms – Two LWT zones"
44] and
Bizone kit installed
#
Code
Description
[9.P.1]
[E-0B]
Bizone kit installed
:
▪
0
No
: The system only has a main zone.
▪
1 N/A
▪
2
Yes
: A bizone kit is installed in order to add
an additional temperature zone.
Summary of Contents for ETSXB16E
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ...4P679467 1C 2023 07 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...