EHBH/X16
Daikin Altherma - Low Temperature Split
4P313776-1 – 2012.05
Installer reference guide
8
5 Application guidelines
Q
To deviate from your daily needs, you can temporarily
overrule the preset values and schedules, use the holiday
mode…
Under floor heating or radiators – Wireless room
thermostat
Setup
Q
The under floor heating or radiators are directly connected to the
indoor unit.
Q
The room temperature is controlled by the wireless external
room thermostat (optional equipment EKRTR1).
Configuration
Benefits
Q
Wireless
.
The Daikin external room thermostat is available in a
wireless version.
Q
Efficiency
.
Although the external room thermostat only sends
ON/OFF signals, it is specifically designed for the heat pump
system.
Q
Comfort
.
In case of under floor heating, the wireless external
room thermostat prevents condensation on the floor during
cooling operation by measuring the room humidity.
Heat pump convectors
Setup
Q
The heat pump convectors are directly connected to the indoor
unit.
Q
The desired room temperature is set via the remote controller of
the heat pump convectors.
Q
The space heating/cooling demand signal is sent to one digital
input on the indoor unit (X2M/1 and X2M/4).
Q
The space operation mode is sent to the heat pump convectors
by one digital output on the indoor unit (X2M/33 and X2M/34).
Configuration
Benefits
Q
Cooling
.
The heat pump convector offers, besides heating
capacity, also excellent cooling capacity.
Q
Efficiency
.
Optimal energy efficiency because of the interlink
function.
Q
Stylish
.
Combination: Under floor h Heat pump
convectors
Q
Space heating is provided by:
Q
The under floor heating
Q
The heat pump convectors
Q
Space cooling is provided by the heat pump convectors only.
The under floor heating is shut off by the shut-off valve.
A
Main leaving water temperature zone
B
One single room
a
Receiver for wireless external room thermostat
b
Wireless external room thermostat
Setting
Value
Unit temperature control:
Q
#: [A.2.1.7]
Q
Code: [C-07]
1 (Ext RT control): Unit operation
is decided by the external
thermostat.
Number of water temperature
zones:
Q
#: [A.2.1.8]
Q
Code: [7-02]
0 (1 LWT zone): Main
External room thermostat for the
main
zone:
Q
#: [A.2.2.4]
Q
Code: [C-05]
Configure according to the setup:
Q
1 (Thermo ON/OFF): When
the used external room
thermostat or heat pump
convector can only send a
thermo ON/OFF condition.
No separation between
heating or cooling demand.
Q
2 (C/H request): When the
used external room
thermostat can send a
separate heating/cooling
thermo ON/OFF condition.
B
A
b
a
A
Main leaving water temperature zone
B
One single room
a
Remote controller of the heat pump convectors
INFORMATION
When using multiple heat pump convectors, make sure
each one receives the infrared signal from the remote
controller of the heat pump convectors.
Setting
Value
Unit temperature control:
Q
#: [A.2.1.7]
Q
Code: [C-07]
1 (Ext RT control): Unit operation
is decided by the external
thermostat.
Number of water temperature
zones:
Q
#: [A.2.1.8]
Q
Code: [7-02]
0 (1 LWT zone): Main
External room thermostat for the
main
zone:
Q
#: [A.2.2.4]
Q
Code: [C-05]
1 (Thermo ON/OFF): When the
used external room thermostat or
heat pump convector can only
send a thermo ON/OFF
condition. No separation
between heating or cooling
demand.