![background image](http://html1.mh-extra.com/html/daikin/erhq011ba/erhq011ba_installers-reference-manual_4704538031.webp)
EHBH/X16
Daikin Altherma - Low Temperature Split
4P313776-1 – 2012.05
Installer reference guide
30
7 Installation
7.4.10 To connect the space cooling/heating
ON/OFF output
1
Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
7.4.11 To connect the changeover to external heat
source
1
Connect the changeover to external heat source cable to the
appropriate terminals as shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
7.4.12 To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
7.5
Finishing the indoor unit installation
7.5.1 To fix the user interface cover to the indoor
unit
1
Make sure that the front panel is removed from the indoor unit.
See To open the indoor unit.
2
Plug the hinges into the backside of the front panel.
3
Plug the user interface cover into the hinges.
4
Mount the front panel to the indoor unit.
7.5.2 To close the indoor unit
1
Close the switch box cover.
2
Reinstall the front panel.
a
Installation of EKRP1HB is required.
a
Installation of EKRP1HB is required.
a
Installation of EKRP1AHTA is required.
X1M
X2M
29
X1M
YC
Y1
Y2
Y3
Y4
A4P
X2M
a
X1M
X1M
X3 X4
A4P
L N
X2M
X1 X2
a
X1M
X2M
12
3
4
5
A8P
X801M
S6S
S7S
S8S
S9S
a
NOTICE
When closing the indoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.